Sensitivity and Specificity of <scp>ELISA</scp> Tests Detecting <scp>BP180</scp> and <scp>BP230</scp> Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis

Bullous pemphigoid (BP) is the most common autoimmune blistering disorder, mainly affecting elderly patients. Enzyme-linked immunosorbent assays (ELISA) targeting BP180 and BP230 autoantibodies are widely used in clinical practice, but their diagnostic accuracy has varied across studies. We conducted a systematic review and meta-analysis to evaluate the pooled diagnostic performance of these assays. Following PRISMA 2020 guidelines, we searched PubMed, Embase, and CENTRAL up to January 12, 2025, for studies assessing BP180 and/or BP230 ELISA in patients with clinically and/or immunopathologically confirmed BP. Seventeen studies including 1768 BP patients and 1382 controls met the inclusion criteria. Data extraction and risk of bias assessment were performed independently by two reviewers, and pooled estimates were calculated using a bivariate random-effects model. For BP180 ELISA, pooled sensitivity was 82.0% (95% confidence interval [CI]: 75.9%-86.8%) and specificity 94.1%. In contrast, BP230 ELISA demonstrated lower sensitivity at 58.6% (95% CI: 51.2%-65.7%) but maintained high specificity of 94.8% (95% CI 89.0-97.7). Risk of bias was generally low. Certainty of evidence, assessed with GRADE, was rated high for BP180 and low for BP230 due to imprecision and publication bias. Overall, BP180 ELISA shows high diagnostic accuracy and supports its use as a reliable, non-invasive diagnostic tool in routine practice. BP230 ELISA, although less sensitive, is best used as an adjunctive/confirmatory assay. These findings highlight the clinical value of serological assays in the diagnostic workup of bullous pemphigoid.

Authors

Institutions

Publication Details

Journal
International Journal of Dermatology
Published
2025-11-12
DOI
https://doi.org/10.1111/ijd.70136
Primary Topic
Autoimmune Bullous Skin Diseases
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis

Anna D. Grabowska, Paulina Barasińska, Marcin Czop, Marta Matych et al.
International Journal of Dermatology
Autoimmune Bullous Skin Diseases
article

Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis

Anna D. Grabowska, Paulina Barasińska, Marcin Czop, Marta Matych, Katarzyna Kulig, Aleksandra Lesiak, Hendri H. Pas, Joanna Narbutt, Monika Grochowska‐Rak, Violetta Karlińska‐Jonkisz, Paweł Racisz
article en

Abstract

Bullous pemphigoid (BP) is the most common autoimmune blistering disorder, mainly affecting elderly patients. Enzyme-linked immunosorbent assays (ELISA) targeting BP180 and BP230 autoantibodies are widely used in clinical practice, but their diagnostic accuracy has varied across studies. We conducted a systematic review and meta-analysis to evaluate the pooled diagnostic performance of these assays. Following PRISMA 2020 guidelines, we searched PubMed, Embase, and CENTRAL up to January 12, 2025, for studies assessing BP180 and/or BP230 ELISA in patients with clinically and/or immunopathologically confirmed BP. Seventeen studies including 1768 BP patients and 1382 controls met the inclusion criteria. Data extraction and risk of bias assessment were performed independently by two reviewers, and pooled estimates were calculated using a bivariate random-effects model. For BP180 ELISA, pooled sensitivity was 82.0% (95% confidence interval [CI]: 75.9%-86.8%) and specificity 94.1%. In contrast, BP230 ELISA demonstrated lower sensitivity at 58.6% (95% CI: 51.2%-65.7%) but maintained high specificity of 94.8% (95% CI 89.0-97.7). Risk of bias was generally low. Certainty of evidence, assessed with GRADE, was rated high for BP180 and low for BP230 due to imprecision and publication bias. Overall, BP180 ELISA shows high diagnostic accuracy and supports its use as a reliable, non-invasive diagnostic tool in routine practice. BP230 ELISA, although less sensitive, is best used as an adjunctive/confirmatory assay. These findings highlight the clinical value of serological assays in the diagnostic workup of bullous pemphigoid.

International Journal of Dermatology
Medical University of Lublin (PL), University Medical Center Groningen (NL), University of Groningen (NL), John Paul II Hospital (PL), Skin Research Center (FR)
Uniwersytet Łódzki
Openalex Percentile: Top 53%
Autoimmune Bullous Skin Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.