Intercomparison of online and offline XRF spectrometers for determining the PM <sub>10</sub> elemental composition of ambient aerosol

Abstract. Measuring the elemental composition of atmospheric particulate matter (PM) can provide useful information on the adverse effects of PM and facilitate the identification of emission sources. Carrying out these measurements at a high temporal resolution (1 h or less) allows describing the fast processes to which aerosol particles are subjected in the atmosphere, leading to a better characterization of the emissions. Energy dispersive X-ray fluorescence (ED-XRF) spectrometry is one of the most widespread techniques used to determine the elemental composition of PM. In recent years, new systems known as online XRF spectrometers have been developed to provide real-time measurements of the PM elemental concentration at a high temporal resolution. Among these advanced instruments, the Xact® 625i Ambient Metals Monitor by Cooper Environmental (USA) performs in situ automated measurements with a user-selected temporal resolution ranging from 15 to 240 min. In this study, an Xact® 625i monitor equipped with a PM10 inlet was deployed for nearly 6 months (July–December 2023) in Milan (Po Valley, Italy) at a monitoring station of the Lombardy Regional Agency for Environmental Protection (ARPA Lombardia). The instrument was configured to quantify 36 elements, ranging from Al to Bi, with 1 h temporal resolution in the PM10 fraction. The objective of the study was to verify the correct functioning of the instrument and to evaluate the quality and robustness of the data produced. Xact® 625i data were aggregated to 24 h daily means and then compared to 24 h PM10 filter data retrieved by ARPA Lombardia in the same station and analyzed offline for the elemental concentration with a benchtop ED-XRF spectrometer. The intercomparison focused on 16 elements (Al, Si, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr, and Pb) whose concentrations were consistently above their minimum detection limits (MDLs) for both online and offline techniques. The results of the intercomparison were satisfying, showing that the Xact® 625i elemental concentrations were highly correlated to the offline ED-XRF analyses (R2 ranging from 0.67 to 0.99 and slopes ranging from 0.79 to 1.3, with only a few elements showing slopes up to 1.70).

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-11-12
DOI
https://doi.org/10.5194/amt-18-6435-2025
Citations
2
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intercomparison of online and offline XRF spectrometers for determining the PM 10 elemental composition of ambient aerosol

Andrê S. H. Prévôt, Benjamin Chazeau, R. Vecchi, Eleonora Cuccia et al.
2 citations
Atmospheric measurement techniques
Atmospheric chemistry and aerosols
2.60
article

Intercomparison of online and offline XRF spectrometers for determining the PM 10 elemental composition of ambient aerosol

Andrê S. H. Prévôt, Benjamin Chazeau, R. Vecchi, Eleonora Cuccia, Manousos-Ioannis Manousakas, Cristina Colombi, Beatrice Biffi, Laura Cadeo, Kaspar R. Daellenbach, Rosario Cosenza
article en
2 citations

Abstract

Abstract. Measuring the elemental composition of atmospheric particulate matter (PM) can provide useful information on the adverse effects of PM and facilitate the identification of emission sources. Carrying out these measurements at a high temporal resolution (1 h or less) allows describing the fast processes to which aerosol particles are subjected in the atmosphere, leading to a better characterization of the emissions. Energy dispersive X-ray fluorescence (ED-XRF) spectrometry is one of the most widespread techniques used to determine the elemental composition of PM. In recent years, new systems known as online XRF spectrometers have been developed to provide real-time measurements of the PM elemental concentration at a high temporal resolution. Among these advanced instruments, the Xact® 625i Ambient Metals Monitor by Cooper Environmental (USA) performs in situ automated measurements with a user-selected temporal resolution ranging from 15 to 240 min. In this study, an Xact® 625i monitor equipped with a PM10 inlet was deployed for nearly 6 months (July–December 2023) in Milan (Po Valley, Italy) at a monitoring station of the Lombardy Regional Agency for Environmental Protection (ARPA Lombardia). The instrument was configured to quantify 36 elements, ranging from Al to Bi, with 1 h temporal resolution in the PM10 fraction. The objective of the study was to verify the correct functioning of the instrument and to evaluate the quality and robustness of the data produced. Xact® 625i data were aggregated to 24 h daily means and then compared to 24 h PM10 filter data retrieved by ARPA Lombardia in the same station and analyzed offline for the elemental concentration with a benchtop ED-XRF spectrometer. The intercomparison focused on 16 elements (Al, Si, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr, and Pb) whose concentrations were consistently above their minimum detection limits (MDLs) for both online and offline techniques. The results of the intercomparison were satisfying, showing that the Xact® 625i elemental concentrations were highly correlated to the offline ED-XRF analyses (R2 ranging from 0.67 to 0.99 and slopes ranging from 0.79 to 1.3, with only a few elements showing slopes up to 1.70).

Atmospheric measurement techniquesVol. 18(21)
Centre National de la Recherche Scientifique (FR), University of Milan (IT), Aix-Marseille Université (FR), Paul Scherrer Institute (CH), Lombardia Informatica (Italy) (IT)
Università degli Studi di Milano, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Openalex Percentile: Top 9%
Atmospheric chemistry and aerosols
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.