SPEED-TR: a self-distilled and pre-trained transformer model for enhanced ECG detection of tricuspid regurgitation

Tricuspid regurgitation (TR) remains underdiagnosed due to the lack of effective screening tools. We developed a self-distilled and pre-trained transformer model for detecting TR (SPEED-TR) from electrocardiography. The model was trained using 466,149 electrocardiogram-echocardiogram pairs from 291,673 patients and validated in one internal (63,925 patients) and two external cohorts (44,951 and 21,300 patients). SPEED-TR accurately detected moderate-to-severe TR in the hold-out set (AUROC 0.945, NPV 0.983; specificity 0.973) and maintained stable performance in multi-center testing sets (AUROCs 0.939-0.943; NPVs 0.978-0.988). Three thresholds enabled SPEED-TR severity grading: none (0-0.008), mild (0.008-0.255), moderate (0.255-0.755), and severe (0.755-1), achieving accuracies of 0.749 (hold-out), 0.730 (internal), 0.775 and 0.726 (external), with overall accuracy of 0.744. SPEED-TR remained robust in patients with 1 to ≥3 risk factors and 1 to ≥2 valvular diseases. SPEED-TR demonstrated potential as a screening tool and may provide reference for TR severity assessment.

Authors

Institutions

Publication Details

Journal
npj Digital Medicine
Published
2025-11-12
DOI
https://doi.org/10.1038/s41746-025-02011-4
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SPEED-TR: a self-distilled and pre-trained transformer model for enhanced ECG detection of tricuspid regurgitation

Zhihui Cao, Wei Zhao, Yanni Huo, Jia He et al.
npj Digital Medicine
Cardiac Valve Diseases and Treatments
article

SPEED-TR: a self-distilled and pre-trained transformer model for enhanced ECG detection of tricuspid regurgitation

Zhihui Cao, Wei Zhao, Yanni Huo, Jia He, Xiaolin Diao, Xiaohan Fan, Huaibing Cheng, Fang Liu, Ya Zhou, Jinghan Huang, Yang Liu, Wei Xu, Xue Zhang, Jizhou Lu
article en

Abstract

Tricuspid regurgitation (TR) remains underdiagnosed due to the lack of effective screening tools. We developed a self-distilled and pre-trained transformer model for detecting TR (SPEED-TR) from electrocardiography. The model was trained using 466,149 electrocardiogram-echocardiogram pairs from 291,673 patients and validated in one internal (63,925 patients) and two external cohorts (44,951 and 21,300 patients). SPEED-TR accurately detected moderate-to-severe TR in the hold-out set (AUROC 0.945, NPV 0.983; specificity 0.973) and maintained stable performance in multi-center testing sets (AUROCs 0.939-0.943; NPVs 0.978-0.988). Three thresholds enabled SPEED-TR severity grading: none (0-0.008), mild (0.008-0.255), moderate (0.255-0.755), and severe (0.755-1), achieving accuracies of 0.749 (hold-out), 0.730 (internal), 0.775 and 0.726 (external), with overall accuracy of 0.744. SPEED-TR remained robust in patients with 1 to ≥3 risk factors and 1 to ≥2 valvular diseases. SPEED-TR demonstrated potential as a screening tool and may provide reference for TR severity assessment.

npj Digital MedicineVol. 8(1)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), National Health and Family Planning Commission (CN), Fu Wai Hospital (CN)
China Postdoctoral Science Foundation
Openalex Percentile: Top 49%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.