Autofluorescence of Renal Tissue and Its Impact on Fluorescence‐Guided Lithotripsy

When illuminated with green light, tissue shows negligible autofluorescence in comparison to urinary stones. In automatically controlled lithotripsy, this property is utilized to prevent the laser from being triggered if the fiber is mispositioned: the fluorescence signal is compared to a set threshold before each pulse. However, previous studies have shown that tissue damage cannot be completely ruled out. We are investigating this phenomenon and its impact on fluorescence guidance. An experiment with porcine calyx (with the automatic control switched off) shows that single Ho:YAG laser pulses are sufficient to coagulate tissue, resulting in an increase in autofluorescence. During lithotripsy of fluorescent artificial stones embedded in renal cortex, thermal damage occurs despite automatic laser control. Maximum fluorescence values measured on those tissue places were above the control's set threshold for laser emission. Therefore, an increase in autofluorescence in the event of denaturation must be considered when using automatically controlled lithotripsy.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-11-10
DOI
https://doi.org/10.1002/jbio.202500430
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autofluorescence of Renal Tissue and Its Impact on Fluorescence‐Guided Lithotripsy

Christopher Kren, Birgit Lange, Ralf Brinkmann
Journal of Biophotonics
Kidney Stones and Urolithiasis Treatments
article

Autofluorescence of Renal Tissue and Its Impact on Fluorescence‐Guided Lithotripsy

Christopher Kren, Birgit Lange, Ralf Brinkmann
article en

Abstract

When illuminated with green light, tissue shows negligible autofluorescence in comparison to urinary stones. In automatically controlled lithotripsy, this property is utilized to prevent the laser from being triggered if the fiber is mispositioned: the fluorescence signal is compared to a set threshold before each pulse. However, previous studies have shown that tissue damage cannot be completely ruled out. We are investigating this phenomenon and its impact on fluorescence guidance. An experiment with porcine calyx (with the automatic control switched off) shows that single Ho:YAG laser pulses are sufficient to coagulate tissue, resulting in an increase in autofluorescence. During lithotripsy of fluorescent artificial stones embedded in renal cortex, thermal damage occurs despite automatic laser control. Maximum fluorescence values measured on those tissue places were above the control's set threshold for laser emission. Therefore, an increase in autofluorescence in the event of denaturation must be considered when using automatically controlled lithotripsy.

Journal of BiophotonicsVol. 19(3)
Medizinisches Laserzentrum Lübeck (Germany) (DE), University of Lübeck (DE)
Openalex Percentile: Top 51%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Autofluorescence of Renal Tissue and Its Impact on Fluorescence‐Guided Lithotripsy — Christopher Kren, Birgit Lange, et al. · Journal of Biophotonics (2025) | TGRS Research Map | TGRS