Continuous electrocardiogram monitoring in porcine model of myocardial ischemia reperfusion

As cardiovascular disease is the leading cause of global mortality, innovative animal models are vital to demonstrating the translational value of experimental discoveries. Investigations focused on myocardial remodeling after ischemia reperfusion (I/R) are well suited to a porcine model, but the evolution of that injury and its impact on electrical conductivity or arrhythmia threshold have been difficult to monitor continuously. Multiple electrode telemetry devices may be fitted to the animals but are costly and prone to damage. Implantable telemetry devices are likewise expensive, carry surgical risk, and are often verified only for single use. Here, we report the utilization of the commercially available Fourth Frontier X2 external telemetry device for continuous monitoring of heart rate and rhythm after myocardial I/R injury in pigs, highlighting sustained monitoring across a 7-day study.

Authors

Institutions

Publication Details

Journal
Animal Models and Experimental Medicine
Published
2025-11-11
DOI
https://doi.org/10.1002/ame2.70103
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous electrocardiogram monitoring in porcine model of myocardial ischemia reperfusion

Nathaniel Hyams, Kristi L. Helke, Sharon Thomas, Ying Mei et al.
Animal Models and Experimental Medicine
Cardiac electrophysiology and arrhythmias
article

Continuous electrocardiogram monitoring in porcine model of myocardial ischemia reperfusion

Nathaniel Hyams, Kristi L. Helke, Sharon Thomas, Ying Mei, Alison B. Hickman, Jean Marie Ruddy, Daniel E. Eldridge, Rupak Mukherjee, Roxanne Swagel
article en

Abstract

As cardiovascular disease is the leading cause of global mortality, innovative animal models are vital to demonstrating the translational value of experimental discoveries. Investigations focused on myocardial remodeling after ischemia reperfusion (I/R) are well suited to a porcine model, but the evolution of that injury and its impact on electrical conductivity or arrhythmia threshold have been difficult to monitor continuously. Multiple electrode telemetry devices may be fitted to the animals but are costly and prone to damage. Implantable telemetry devices are likewise expensive, carry surgical risk, and are often verified only for single use. Here, we report the utilization of the commercially available Fourth Frontier X2 external telemetry device for continuous monitoring of heart rate and rhythm after myocardial I/R injury in pigs, highlighting sustained monitoring across a 7-day study.

Animal Models and Experimental MedicineVol. 9(2)
Medical University of South Carolina (US), Clemson University (US)
National Institutes of Health, South Carolina Clinical and Translational Research Institute, Medical University of South Carolina, National Heart, Lung, and Blood Institute, National Center for Advancing Translational Sciences
Openalex Percentile: Top 49%
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Continuous electrocardiogram monitoring in porcine model of myocardial ischemia reperfusion — Nathaniel Hyams, Kristi L. Helke, et al. · Animal Models and Experimental Medicine (2025) | TGRS Research Map | TGRS