Three‐Dimensional X‐Ray Diffraction Analysis Using Energy‐Dispersive X‐Ray Detector and Straight Capillary Optics

ABSTRACT We developed an X‐ray diffraction technique to measure the three‐dimensional crystal distribution of samples. By using an energy‐dispersive detector and installing two straight X‐ray optics in quasi‐confocal arrangement, an X‐ray diffraction spectrum from a targeted microscopic region of the sample can be obtained while keeping the irradiation and detection angles of the X‐rays on the sample constant. Therefore, the three‐dimensional crystal distribution of a sample can be measured by scanning the quasi‐confocal (intersection) of two straight X‐ray optics. By enabling the sample stand and detector to be driven by a newly added coaxial stepping motor this time, the X‐ray irradiation angle and detected angle can be electrically controlled. Therefore, the appropriate measurement angle can be quickly controlled. Using an energy‐dispersive detector to measure X‐ray diffraction presents an advantage: unlike general X‐ray diffraction measurements, angle scanning is not required at each measurement point, and consequently, the measurement target range does not change. In this study, we demonstrated the developed technique using samples of muscovite film, Si powder, and Ni thin film, and evaluated the spatial resolution of our new technique.

Authors

Institutions

Publication Details

Journal
X-Ray Spectrometry
Published
2025-11-11
DOI
https://doi.org/10.1002/xrs.70055
Primary Topic
Crystallography and Radiation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three‐Dimensional X‐Ray Diffraction Analysis Using Energy‐Dispersive X‐Ray Detector and Straight Capillary Optics

S. Fukumoto, Kouichi Tsuji, Naoya Taniguchi, T. Nishiyama
X-Ray Spectrometry
Crystallography and Radiation Phenomena
article

Three‐Dimensional X‐Ray Diffraction Analysis Using Energy‐Dispersive X‐Ray Detector and Straight Capillary Optics

S. Fukumoto, Kouichi Tsuji, Naoya Taniguchi, T. Nishiyama
article en

Abstract

ABSTRACT We developed an X‐ray diffraction technique to measure the three‐dimensional crystal distribution of samples. By using an energy‐dispersive detector and installing two straight X‐ray optics in quasi‐confocal arrangement, an X‐ray diffraction spectrum from a targeted microscopic region of the sample can be obtained while keeping the irradiation and detection angles of the X‐rays on the sample constant. Therefore, the three‐dimensional crystal distribution of a sample can be measured by scanning the quasi‐confocal (intersection) of two straight X‐ray optics. By enabling the sample stand and detector to be driven by a newly added coaxial stepping motor this time, the X‐ray irradiation angle and detected angle can be electrically controlled. Therefore, the appropriate measurement angle can be quickly controlled. Using an energy‐dispersive detector to measure X‐ray diffraction presents an advantage: unlike general X‐ray diffraction measurements, angle scanning is not required at each measurement point, and consequently, the measurement target range does not change. In this study, we demonstrated the developed technique using samples of muscovite film, Si powder, and Ni thin film, and evaluated the spatial resolution of our new technique.

X-Ray Spectrometry
Osaka Metropolitan University (JP), Tokyo Metropolitan University (JP)
Openalex Percentile: Top 79%
Crystallography and Radiation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.