PhD Forum Abstract: Towards Comfort-Aware and Energy-Efficient Control of Domestic Heat Pumps

Heating decarbonisation demands control strategies that are both effective and transparent. However, in domestic air-source heat pumps, thermostat controller heuristics and system physics often intertwine, making it difficult to reason about energy use or to test alternative control policies. We adopt a clear control boundary: the controller selects a flow-water temperature set-point. A separate system model predicts next-minute flow and return temperatures and instantaneous electrical power from the current state and weather. Using household telemetry, we fit a compact model with a single-step temperature update towards the set-point, thermal power from the flow-return difference, and a coefficient of performance (COP) linked to temperature lift which is the difference between flow and outdoor temperature. Model coefficients are estimated by constrained least squares. Validation uses rolling-origin splits and physics checks (energy balance, sensible COP), with day replays around set-point changes. This ongoing work contributes a clear controller-system separation at the set-point boundary, a small set of physically motivated equations calibrated from household telemetry, and a reproducible protocol that supports counterfactual policy testing and an offline reinforcement learning environment providing a practical route towards improved heat pump control.

Authors

Institutions

Publication Details

Published
2025-11-11
DOI
https://doi.org/10.1145/3736425.3772202
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PhD Forum Abstract: Towards Comfort-Aware and Energy-Efficient Control of Domestic Heat Pumps

Bivin Pradeep
Integrated Energy Systems Optimization
article

PhD Forum Abstract: Towards Comfort-Aware and Energy-Efficient Control of Domestic Heat Pumps

Bivin Pradeep
article en

Abstract

Heating decarbonisation demands control strategies that are both effective and transparent. However, in domestic air-source heat pumps, thermostat controller heuristics and system physics often intertwine, making it difficult to reason about energy use or to test alternative control policies. We adopt a clear control boundary: the controller selects a flow-water temperature set-point. A separate system model predicts next-minute flow and return temperatures and instantaneous electrical power from the current state and weather. Using household telemetry, we fit a compact model with a single-step temperature update towards the set-point, thermal power from the flow-return difference, and a coefficient of performance (COP) linked to temperature lift which is the difference between flow and outdoor temperature. Model coefficients are estimated by constrained least squares. Validation uses rolling-origin splits and physics checks (energy balance, sensible COP), with day replays around set-point changes. This ongoing work contributes a clear controller-system separation at the set-point boundary, a small set of physically motivated equations calibrated from household telemetry, and a reproducible protocol that supports counterfactual policy testing and an offline reinforcement learning environment providing a practical route towards improved heat pump control.

Coventry University (GB)
Openalex Percentile: Top 67%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.