A Compact 2.3 μm DFB-Laser CO Sensor Using MPC-LITES for Real-Time Monitoring of Cigarette Smoke

A compact and high-sensitivity carbon monoxide (CO) detection system based on multi-pass cell enhanced light-induced thermoelastic spectroscopy (MPC-LITES) was developed for real-time monitoring. A 2.3 μm distributed feedback (DFB) diode laser targeting the CO absorption line at 4300.699 cm<sup>-1</sup> was employed, offering strong line intensity and minimal interference from H<sub>2</sub>O, CO<sub>2</sub>, NO<sub>2</sub>, and SO<sub>2</sub>. The optimal modulation depth of 0.76 cm<sup>-1</sup> produced the maximum second harmonic (2<i>f</i>) signal. Experimental results demonstrated excellent linearity (R<sup>2</sup> = 0.998) and a minimum detection limit of 230 ppb at 1 s, further reduced to 47 ppb at 367 s by Allan deviation analysis. Application tests were carried out for real-time monitoring of cigarette smoke in a 20 m<sup>2</sup> indoor environment. Under closed conditions, the CO concentration rapidly increased to approximately 165 ppm, while in ventilated conditions, it peaked at 45 ppm and decayed quickly due to air exchange. The results confirm that the proposed MPC-LITES sensor enables accurate, real-time detection of transient CO variations, demonstrating strong potential for indoor air quality evaluation, environmental safety, and public health protection.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-12
DOI
https://doi.org/10.3390/s25226894
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact 2.3 μm DFB-Laser CO Sensor Using MPC-LITES for Real-Time Monitoring of Cigarette Smoke

Leqing Lin, Wenguo Zhu, Lihao Wang, Jianhui Yu et al.
Sensors
Spectroscopy and Laser Applications
article

A Compact 2.3 μm DFB-Laser CO Sensor Using MPC-LITES for Real-Time Monitoring of Cigarette Smoke

Leqing Lin, Wenguo Zhu, Lihao Wang, Jianhui Yu, Jianfeng He, Haoyang Lin, Huadan Zheng, Hong Guo, Yongchun Zhong, Ruobin Zhuang
article en

Abstract

A compact and high-sensitivity carbon monoxide (CO) detection system based on multi-pass cell enhanced light-induced thermoelastic spectroscopy (MPC-LITES) was developed for real-time monitoring. A 2.3 μm distributed feedback (DFB) diode laser targeting the CO absorption line at 4300.699 cm<sup>-1</sup> was employed, offering strong line intensity and minimal interference from H<sub>2</sub>O, CO<sub>2</sub>, NO<sub>2</sub>, and SO<sub>2</sub>. The optimal modulation depth of 0.76 cm<sup>-1</sup> produced the maximum second harmonic (2<i>f</i>) signal. Experimental results demonstrated excellent linearity (R<sup>2</sup> = 0.998) and a minimum detection limit of 230 ppb at 1 s, further reduced to 47 ppb at 367 s by Allan deviation analysis. Application tests were carried out for real-time monitoring of cigarette smoke in a 20 m<sup>2</sup> indoor environment. Under closed conditions, the CO concentration rapidly increased to approximately 165 ppm, while in ventilated conditions, it peaked at 45 ppm and decayed quickly due to air exchange. The results confirm that the proposed MPC-LITES sensor enables accurate, real-time detection of transient CO variations, demonstrating strong potential for indoor air quality evaluation, environmental safety, and public health protection.

SensorsVol. 25(22)
Jinan University (CN)
Openalex Percentile: Top 69%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.