Highly Sensitive Detection Method of Gas Based on the Fabry–Pérot Cavity Using Terahertz Frequency-Domain Spectroscopy

This study introduces a simple, sensitive, efficient, and low-cost gas detection method in the terahertz range. A mode-adjustable Fabry–Pérot cavity is proposed to enhance detection by tuning the cavity length to match the cavity’s resonant frequency with the gas absorption peak. Terahertz frequency domain spectroscopy (THz-FDS), offering MHz-level resolution, provides stronger applicability than other spectral systems. Carbon monoxide (CO) is used as the test gas, with its 465 GHz absorption peak validating the coupling enhancement. The experiment measures CO absorption spectra from 0.02 to 1.5 THz, achieving a detection limit of 7%. Using a vacuum cavity to eliminate water vapor interference, low concentrations are detected, with a mode number of m = 10 yielding a detection limit of 3500 ppm, 20 times better than previous results. The impact of different modes on coupling was analyzed, showing more effective coupling when the Q-value of the resonant peak closely matches that of the gas absorption peak. This method demonstrates high sensitivity and applicability for detecting low concentrations of toxic and harmful gases.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-11-12
DOI
https://doi.org/10.3390/chemosensors13110394
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Detection Method of Gas Based on the Fabry–Pérot Cavity Using Terahertz Frequency-Domain Spectroscopy

Kanglong Chen, Cunjun Ruan, Ayesha Kosar Fahad, Lulu Han et al.
Chemosensors
Terahertz technology and applications
article

Highly Sensitive Detection Method of Gas Based on the Fabry–Pérot Cavity Using Terahertz Frequency-Domain Spectroscopy

Kanglong Chen, Cunjun Ruan, Ayesha Kosar Fahad, Lulu Han, Yubo Wu
article en

Abstract

This study introduces a simple, sensitive, efficient, and low-cost gas detection method in the terahertz range. A mode-adjustable Fabry–Pérot cavity is proposed to enhance detection by tuning the cavity length to match the cavity’s resonant frequency with the gas absorption peak. Terahertz frequency domain spectroscopy (THz-FDS), offering MHz-level resolution, provides stronger applicability than other spectral systems. Carbon monoxide (CO) is used as the test gas, with its 465 GHz absorption peak validating the coupling enhancement. The experiment measures CO absorption spectra from 0.02 to 1.5 THz, achieving a detection limit of 7%. Using a vacuum cavity to eliminate water vapor interference, low concentrations are detected, with a mode number of m = 10 yielding a detection limit of 3500 ppm, 20 times better than previous results. The impact of different modes on coupling was analyzed, showing more effective coupling when the Q-value of the resonant peak closely matches that of the gas absorption peak. This method demonstrates high sensitivity and applicability for detecting low concentrations of toxic and harmful gases.

ChemosensorsVol. 13(11)
Zhejiang International Studies University (CN), Beihang University (CN)
National Natural Science Foundation of China, Tsinghua University
Openalex Percentile: Top 67%
Terahertz technology and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.