Two-stage calibration method for portable light pen of vision based coordinate measurement system

Portable light pen measurement technology is widely applied in manufacturing, industrial inspection, and other engineering fields. To address the decline in measurement accuracy caused by marker points localization errors and probe center displacement in light pen systems, this paper proposes a two-stage self-calibration method based on distance constraints and geometric optimization. Unlike previous methods that rely on coordinate measurement machines to obtain marker points coordinates and distance parameters, the proposed method only utilizes image-based information for calibration. In the first stage, a sensitivity analysis of the ideal marker coordinates is conducted, followed by a trust-region optimization algorithm incorporating weighting and regularization to estimate the distances between marker points and the probe center. In the second stage, bundle adjustment with geometric constraints optimizes the marker points coordinates. Experimental results indicate that the repeatability accuracy of the probe center coordinates, as determined by the proposed method, reaches 50 μm in the X, Y, and Z directions. Additionally, measurements of standard parts indicate that the distance measurement deviation is less than 70 μm.

Authors

Publication Details

Journal
Optics Express
Published
2025-11-12
DOI
https://doi.org/10.1364/oe.577033
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-stage calibration method for portable light pen of vision based coordinate measurement system

Songxiao Cao, Bin Guo, Yang Wang, Zhihai Xu et al.
Optics Express
Optical measurement and interference techniques
article

Two-stage calibration method for portable light pen of vision based coordinate measurement system

Songxiao Cao, Bin Guo, Yang Wang, Zhihai Xu, Tao Song
article en

Abstract

Portable light pen measurement technology is widely applied in manufacturing, industrial inspection, and other engineering fields. To address the decline in measurement accuracy caused by marker points localization errors and probe center displacement in light pen systems, this paper proposes a two-stage self-calibration method based on distance constraints and geometric optimization. Unlike previous methods that rely on coordinate measurement machines to obtain marker points coordinates and distance parameters, the proposed method only utilizes image-based information for calibration. In the first stage, a sensitivity analysis of the ideal marker coordinates is conducted, followed by a trust-region optimization algorithm incorporating weighting and regularization to estimate the distances between marker points and the probe center. In the second stage, bundle adjustment with geometric constraints optimizes the marker points coordinates. Experimental results indicate that the repeatability accuracy of the probe center coordinates, as determined by the proposed method, reaches 50 μm in the X, Y, and Z directions. Additionally, measurements of standard parts indicate that the distance measurement deviation is less than 70 μm.

Optics ExpressVol. 33(24)
Openalex Percentile: Top 66%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.