LITES-based methane isotope ratio measurement and source attribution

This work presents what we believe to be the first application of light-induced thermoelastic spectroscopy (LITES) to methane isotope detection, demonstrating the development of a compact, low-power system. By targeting the near-infrared absorption lines of the two isotopologues <sup>13</sup>CH<sub>4</sub> and <sup>12</sup>CH<sub>4</sub> and applying Kalman filtering, the system simultaneously measures their absolute concentrations and isotopic abundance ratio while achieving improved signal-to-noise performance. Experimental validation with chemically synthesized methane and biogas from a wastewater treatment plant demonstrates that the isotopic ratios obtained are in excellent agreement with high-precision mass spectrometry, allowing reliable discrimination of methane sources. This study establishes LITES as a promising approach for portable, low-power, and in situ isotope monitoring.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-11-12
DOI
https://doi.org/10.1364/oe.581062
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
2.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LITES-based methane isotope ratio measurement and source attribution

Renjie Cui, Lei Dong, Jialiang Dai, Haofeng Zhang et al.
3 citations
Optics Express
Spectroscopy and Laser Applications
2.27
article

LITES-based methane isotope ratio measurement and source attribution

Renjie Cui, Lei Dong, Jialiang Dai, Haofeng Zhang, Xukun Yin, Gang Zhao, Yang Wang, Yifan Chen, Wei Xiao, Hongpeng Wu, Wenjie Zhang, Bing Luo, Weiguang Ma
article en
3 citations

Abstract

This work presents what we believe to be the first application of light-induced thermoelastic spectroscopy (LITES) to methane isotope detection, demonstrating the development of a compact, low-power system. By targeting the near-infrared absorption lines of the two isotopologues <sup>13</sup>CH<sub>4</sub> and <sup>12</sup>CH<sub>4</sub> and applying Kalman filtering, the system simultaneously measures their absolute concentrations and isotopic abundance ratio while achieving improved signal-to-noise performance. Experimental validation with chemically synthesized methane and biogas from a wastewater treatment plant demonstrates that the isotopic ratios obtained are in excellent agreement with high-precision mass spectrometry, allowing reliable discrimination of methane sources. This study establishes LITES as a promising approach for portable, low-power, and in situ isotope monitoring.

Optics ExpressVol. 33(24)
Electric Power Research Institute (US), Xidian University (CN)
Openalex Percentile: Top 11%
Spectroscopy and Laser Applications
2.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.