Experimental and Numerical Study on Fire Resistance and Residual Strength of Prefabricated Utility Tunnels
Fire hazard presents a critical challenge to the structural reliability of underground modular infrastructure. This study examines the fire resistance performance of prefabricated monolithic utility tunnels featuring longitudinal threaded connections. A series of fire exposure tests was conducted on assembled utility tunnel specimens using different bolt materials and thermal conditions, enabling evaluation of fire behavior, deformation behavior, and residual capacity. The observed thermal properties revealed significant temperature gradients across tunnel sections, with the peak internal–external differential reaching 536.8 °C. Post-fire mechanical degradation was evident in reduced stiffness and ductility, and the residual load-bearing capacity declined by up to 12.28% compared to unexposed specimens. Specimens using high-strength threaded bolts demonstrated superior performance compared to stainless steel bolt specimens, exhibiting a 4.67% higher residual capacity and 13.87% less residual deformation. A sequential thermal–mechanical finite element model was developed and calibrated based on experimental results, offering a reliable simulation framework for investigating fire-induced damage and residual strength in modular utility tunnel systems. These findings provide a quantitative basis for fire safety assessment.
Authors
- Qi Yuan (ORCID: https://orcid.org/0000-0001-7005-0685)
- Zigen Li
- Hongbo Li (ORCID: https://orcid.org/0000-0001-8662-0427)
- Binlin Zhang (ORCID: https://orcid.org/0009-0003-6311-7804)
Institutions
- Jilin Jianzhu University (CN)
Publication Details
- Journal
- Buildings
- Published
- 2025-11-11
- DOI
- https://doi.org/10.3390/buildings15224062
- Primary Topic
- Fire effects on concrete materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00