A Billet Surface Temperature Measurement Method Based on a Water Mist Dehazing Network

In this paper, we present a water mist dehazing network to improve the accuracy of radiation temperature measurements of the billet surface in the secondary cooling zone of continuous casting. First, we develop a billet radiation attenuation model that accounts for the wavelength-dependent attenuation coefficient of water mist in the secondary cooling zone. Using this model and the corresponding dataset, the water mist transmittance is calculated. Furthermore, the water mist dehazing network—which is distinct from conventional dehazing networks designed for natural environments—comprises three key components: water mist feature extraction based on a combined Unet and Transformer structure; fusion of prior water mist transmittance data using an attention mechanism; and composite transmittance estimation via a multi-path dense network. The experimental results demonstrate that the proposed network effectively reduces water mist’s interference with billet surface temperature measurements in both the spatial and temporal dimensions. Compared with the standalone Unet and Unet + Transformer network architectures, the proposed network achieves a significantly improved dehazing performance, thus verifying its practical value and reliability for billet surface temperature measurement tasks.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-11
DOI
https://doi.org/10.3390/app152211981
Primary Topic
Radiative Heat Transfer Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Billet Surface Temperature Measurement Method Based on a Water Mist Dehazing Network

Hongji Meng, Jian Yang, Wei Wei, Zhenwei Hu
Applied Sciences
Radiative Heat Transfer Studies
article

A Billet Surface Temperature Measurement Method Based on a Water Mist Dehazing Network

Hongji Meng, Jian Yang, Wei Wei, Zhenwei Hu
article en

Abstract

In this paper, we present a water mist dehazing network to improve the accuracy of radiation temperature measurements of the billet surface in the secondary cooling zone of continuous casting. First, we develop a billet radiation attenuation model that accounts for the wavelength-dependent attenuation coefficient of water mist in the secondary cooling zone. Using this model and the corresponding dataset, the water mist transmittance is calculated. Furthermore, the water mist dehazing network—which is distinct from conventional dehazing networks designed for natural environments—comprises three key components: water mist feature extraction based on a combined Unet and Transformer structure; fusion of prior water mist transmittance data using an attention mechanism; and composite transmittance estimation via a multi-path dense network. The experimental results demonstrate that the proposed network effectively reduces water mist’s interference with billet surface temperature measurements in both the spatial and temporal dimensions. Compared with the standalone Unet and Unet + Transformer network architectures, the proposed network achieves a significantly improved dehazing performance, thus verifying its practical value and reliability for billet surface temperature measurement tasks.

Applied SciencesVol. 15(22)
Liaoning University (CN), Jiangsu Institute of Metrology (CN), Northeastern University (CN)
Openalex Percentile: Top 65%
Radiative Heat Transfer Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.