Data-driven environments: Evaluating IoT sensors and KNX protocol for monitoring indoor conditions in educational facilities

Educational institutions face a growing challenge in creating indoor environments that support both student wellbeing and operational efficiency. This case study, conducted within two university classrooms at the Technical University of Cluj-Napoca, Romania, assesses the reliability of a smart building system deployed to monitor indoor parameters. The system, which features integrated wall-mounted Internet of Things (IoT) sensors communicating via the KNX protocol, is evaluated by benchmarking its performance to that of a professional monitor instrument (Testo 400). The methodology involved a mixed-methods approach, combining quantitative data from the KNX-based automation network and Testo 400 monitor with qualitative feedback from occupants on thermal comfort, humidity, and indoor air quality. While a systematic offset was observed, with the professional monitor yielding higher readings, the KNX system demonstrated notable consistency. The statistical analysis revealed a strong Pearson’s correlation (up to 0.98, p < 0.001) for CO 2 and relative humidity, followed by temperature (up to 0.97). Despite successful thermal comfort maintenance, indoor air quality emerged as a significant concern due to CO 2 levels frequently indicating severe ventilation deficiencies. Comparative analysis showed minimum CO 2 concentrations fell into EN 16798–1:2019 Category II/III, while maximum concentrations exceeded both Category IV (Red rating) and the ASHRAE 62.1–2022 threshold. Beyond validating KNX’s reliability for indoor environmental quality monitoring in this specific context, this case study highlights the critical need for ventilation system upgrades in higher education to effectively control high CO 2 concentrations and foster healthier learning environments.

Authors

Institutions

Publication Details

Journal
Frontiers in Built Environment
Published
2025-11-12
DOI
https://doi.org/10.3389/fbuil.2025.1688582
Citations
3
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
2.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-driven environments: Evaluating IoT sensors and KNX protocol for monitoring indoor conditions in educational facilities

Carmen Maria Mârza, Dana-Adriana Iluţiu-Varvara, Raluca MOLDOVAN, Georgiana Corsiuc et al.
3 citations
Frontiers in Built Environment
Air Quality Monitoring and Forecasting
2.40
article

Data-driven environments: Evaluating IoT sensors and KNX protocol for monitoring indoor conditions in educational facilities

Carmen Maria Mârza, Dana-Adriana Iluţiu-Varvara, Raluca MOLDOVAN, Georgiana Corsiuc, Tania Rus
article en
3 citations

Abstract

Educational institutions face a growing challenge in creating indoor environments that support both student wellbeing and operational efficiency. This case study, conducted within two university classrooms at the Technical University of Cluj-Napoca, Romania, assesses the reliability of a smart building system deployed to monitor indoor parameters. The system, which features integrated wall-mounted Internet of Things (IoT) sensors communicating via the KNX protocol, is evaluated by benchmarking its performance to that of a professional monitor instrument (Testo 400). The methodology involved a mixed-methods approach, combining quantitative data from the KNX-based automation network and Testo 400 monitor with qualitative feedback from occupants on thermal comfort, humidity, and indoor air quality. While a systematic offset was observed, with the professional monitor yielding higher readings, the KNX system demonstrated notable consistency. The statistical analysis revealed a strong Pearson’s correlation (up to 0.98, p < 0.001) for CO 2 and relative humidity, followed by temperature (up to 0.97). Despite successful thermal comfort maintenance, indoor air quality emerged as a significant concern due to CO 2 levels frequently indicating severe ventilation deficiencies. Comparative analysis showed minimum CO 2 concentrations fell into EN 16798–1:2019 Category II/III, while maximum concentrations exceeded both Category IV (Red rating) and the ASHRAE 62.1–2022 threshold. Beyond validating KNX’s reliability for indoor environmental quality monitoring in this specific context, this case study highlights the critical need for ventilation system upgrades in higher education to effectively control high CO 2 concentrations and foster healthier learning environments.

Frontiers in Built EnvironmentVol. 11
Technical University of Cluj-Napoca (RO)
Openalex Percentile: Top 11%
Air Quality Monitoring and Forecasting
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.