Influence of CAD-CAM Materials on Marginal Fit of Single Unit Crowns: An In Vitro SEM-Based Study

Background/Objectives: The marginal adaptation of CAD/CAM restorations remains a key determinant of long-term clinical success, particularly in minimally invasive preparations. This in vitro study evaluated and compared the marginal gap of three CAD/CAM restorative materials—Cerasmart, G-CAM, and IPS Empress CAD—using standardized preparation and SEM measurement protocols. Methods: A total of 18 crowns were fabricated, of which 9 presented margins sufficiently interpretable under SEM and were included in the pooled quantitative analysis (n = 362 measurement points). Marginal gaps were recorded at 45×, 100× and 450× magnification using a Jeol JSM 25S scanning electron microscope. Normality and variance homogeneity were verified prior to parametric testing. Results: When pooled per material group, the mean ± SD marginal gap values were 18.53 ± 14.15 µm for Cerasmart, 21.60 ± 14.89 µm for G-CAM, and 47.09 ± 16.93 µm for IPS Empress CAD. All values fell below the contemporary clinical threshold of <70 µm for adhesive cementation. Pairwise comparison showed a large difference between IPS Empress CAD and the two resin-based materials, whereas the difference between Cerasmart and G-CAM was small. Conclusions: Hybrid and resin nano-ceramic CAD/CAM materials demonstrated narrower marginal gaps compared with the glass ceramic tested, likely due to their lower elastic modulus and greater seating accommodation during cementation. Within the limits of this in vitro design, all materials exhibited marginal adaptation consistent with current clinical acceptability criteria.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2025-11-11
DOI
https://doi.org/10.3390/prosthesis7060147
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of CAD-CAM Materials on Marginal Fit of Single Unit Crowns: An In Vitro SEM-Based Study

Andreea Iuliana Kui, Smaranda Dana Buduru, Andrea Maria Chisnoiu, Simona Iacob et al.
Prosthesis
Dental materials and restorations
article

Influence of CAD-CAM Materials on Marginal Fit of Single Unit Crowns: An In Vitro SEM-Based Study

Andreea Iuliana Kui, Smaranda Dana Buduru, Andrea Maria Chisnoiu, Simona Iacob, Ana‐Maria Condor, Amanda-Lelia Rădulescu, Marius Negucioiu, Bianca Dumbrovca
article en

Abstract

Background/Objectives: The marginal adaptation of CAD/CAM restorations remains a key determinant of long-term clinical success, particularly in minimally invasive preparations. This in vitro study evaluated and compared the marginal gap of three CAD/CAM restorative materials—Cerasmart, G-CAM, and IPS Empress CAD—using standardized preparation and SEM measurement protocols. Methods: A total of 18 crowns were fabricated, of which 9 presented margins sufficiently interpretable under SEM and were included in the pooled quantitative analysis (n = 362 measurement points). Marginal gaps were recorded at 45×, 100× and 450× magnification using a Jeol JSM 25S scanning electron microscope. Normality and variance homogeneity were verified prior to parametric testing. Results: When pooled per material group, the mean ± SD marginal gap values were 18.53 ± 14.15 µm for Cerasmart, 21.60 ± 14.89 µm for G-CAM, and 47.09 ± 16.93 µm for IPS Empress CAD. All values fell below the contemporary clinical threshold of <70 µm for adhesive cementation. Pairwise comparison showed a large difference between IPS Empress CAD and the two resin-based materials, whereas the difference between Cerasmart and G-CAM was small. Conclusions: Hybrid and resin nano-ceramic CAD/CAM materials demonstrated narrower marginal gaps compared with the glass ceramic tested, likely due to their lower elastic modulus and greater seating accommodation during cementation. Within the limits of this in vitro design, all materials exhibited marginal adaptation consistent with current clinical acceptability criteria.

ProsthesisVol. 7(6)
Iuliu Hațieganu University of Medicine and Pharmacy (RO)
Openalex Percentile: Top 61%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.