An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models

Neural implants help understand neurological disorders and are actively used to study deep and cortical brain surface regions. Dealing with cortical surface regions is less complicated in clinical therapy than deep brain regions. Researchers are interested in identifying cortical surface region/s for a particular neurological disorder. Rodent models are extensively used in preclinical studies. Usually, microwires, screws, and grid-type implants are used for such studies, but they are not designed for specific rodent brain regions. Since the grids are typically standard in size, in some cases, the craniotomy required to implant the grid will be significantly bigger than the region of interest, which may pose challenges for chronic studies due to infection. Additionally, the grids may block the nearby brain regions in multisite studies, posing difficulty for another device to be implanted. In this study, a novel L-shaped surface neural implant with five electrodes (diameter: 400 μm) spanning a 1 mm × 3 mm area is fabricated using biocompatible Polyimide material for cortical surface studies. The overall thickness of the neural implant is around 25 μm. The average impedance of the electrodes is 18.315 kΩ at 1 kHz. A bilateral craniotomy is performed to place the neural implants in the secondary motor area for subdural chronic electrocorticography (ECoG) signal acquisition in control and hemi parkinsonian rats. After the recovery period, the ECoG signals are acquired using the Open BCI Cyton Daisy Biosensing board for two weeks from the rats.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-11
DOI
https://doi.org/10.1038/s41598-025-23049-0
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models

R Krishnakumaran, Hardik J. Pandya, K. V. Shabari Girishan, Sreenivas Bhaskara et al.
Scientific Reports
Neuroscience and Neural Engineering
article

An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models

R Krishnakumaran, Hardik J. Pandya, K. V. Shabari Girishan, Sreenivas Bhaskara, Anand Arun Dwivedi, Saravanan Murugaiyan
article en

Abstract

Neural implants help understand neurological disorders and are actively used to study deep and cortical brain surface regions. Dealing with cortical surface regions is less complicated in clinical therapy than deep brain regions. Researchers are interested in identifying cortical surface region/s for a particular neurological disorder. Rodent models are extensively used in preclinical studies. Usually, microwires, screws, and grid-type implants are used for such studies, but they are not designed for specific rodent brain regions. Since the grids are typically standard in size, in some cases, the craniotomy required to implant the grid will be significantly bigger than the region of interest, which may pose challenges for chronic studies due to infection. Additionally, the grids may block the nearby brain regions in multisite studies, posing difficulty for another device to be implanted. In this study, a novel L-shaped surface neural implant with five electrodes (diameter: 400 μm) spanning a 1 mm × 3 mm area is fabricated using biocompatible Polyimide material for cortical surface studies. The overall thickness of the neural implant is around 25 μm. The average impedance of the electrodes is 18.315 kΩ at 1 kHz. A bilateral craniotomy is performed to place the neural implants in the secondary motor area for subdural chronic electrocorticography (ECoG) signal acquisition in control and hemi parkinsonian rats. After the recovery period, the ECoG signals are acquired using the Open BCI Cyton Daisy Biosensing board for two weeks from the rats.

Scientific ReportsVol. 15(1)
M S Ramaiah Memorial Hospital (IN), Indian Institute of Science Bangalore (IN)
Openalex Percentile: Top 63%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models — R Krishnakumaran, Hardik J. Pandya, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS