Cyclic performance of pre-engineered beam-column connections for mass timber and hybrid mass timber-steel structures

Pre-engineered hanger connections are commonly used as beam-column connections in the gravity load carrying system of mass timber or hybrid timber-steel structures. While these connections are relied upon to transfer shear forces, they must also have sufficient rotation capacity to withstand a design-level earthquake without losing their load-carrying capacities. This study investigates the rotation capacities of two commonly used pre-engineered beam-column connections, including a bolt and collar style connection as well as an interlocking jaw connection. The influence of several parameters on the cyclic performance of the connectors are investigated, including the influence of gravity load, screw configuration, and the installation of two connectors side-by-side on the beam and column face. Furthermore, the cyclic behaviour of a series of connections with a steel column investigating the influence of weld configuration are also presented. Results of the study demonstrate that the bolt and collar consistently achieved maximum rotation capacity beyond 0.06 rad prior to losing their shear carrying capacity while the interlocking jaw connections achieved rotations above 0.08 rad without losing their shear carrying capacity. Placing two connectors in parallel did not change the rotation capacity of the connector. The weld configuration in timber-steel connections had an influence on rotational stiffness and maximum rotation capacity. Ultimately, all the tested connections met the rotation required to meet North American lateral drift limits. • Experiments on pre-engineered timber and timber-steel beam-column connections conducted under combined shear and cyclic rotation. • Influence of connection type, gravity loading, screw configuration, and multiple connectors placed side-by-side studied. • Interlocking jaw (Megant 430 ×150) and bolt and collar (Ricon 390 ×80) achieved maximum rotations beyond 0.06 rad. • Placing multiple bolt and collar connectors side-by-side on the beam/column face does not influence rotation capacity. • Welded bolt and collar connections achieved significant rotation capacities (>0.07 rad) but depends on weld configuration.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-11-11
DOI
https://doi.org/10.1016/j.engstruct.2025.121683
Citations
1
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyclic performance of pre-engineered beam-column connections for mass timber and hybrid mass timber-steel structures

Joshua E. Woods, Andrew Wierzbowski
1 citations
Engineering Structures
Wood Treatment and Properties
1.01
article

Cyclic performance of pre-engineered beam-column connections for mass timber and hybrid mass timber-steel structures

Joshua E. Woods, Andrew Wierzbowski
article en
1 citations

Abstract

Pre-engineered hanger connections are commonly used as beam-column connections in the gravity load carrying system of mass timber or hybrid timber-steel structures. While these connections are relied upon to transfer shear forces, they must also have sufficient rotation capacity to withstand a design-level earthquake without losing their load-carrying capacities. This study investigates the rotation capacities of two commonly used pre-engineered beam-column connections, including a bolt and collar style connection as well as an interlocking jaw connection. The influence of several parameters on the cyclic performance of the connectors are investigated, including the influence of gravity load, screw configuration, and the installation of two connectors side-by-side on the beam and column face. Furthermore, the cyclic behaviour of a series of connections with a steel column investigating the influence of weld configuration are also presented. Results of the study demonstrate that the bolt and collar consistently achieved maximum rotation capacity beyond 0.06 rad prior to losing their shear carrying capacity while the interlocking jaw connections achieved rotations above 0.08 rad without losing their shear carrying capacity. Placing two connectors in parallel did not change the rotation capacity of the connector. The weld configuration in timber-steel connections had an influence on rotational stiffness and maximum rotation capacity. Ultimately, all the tested connections met the rotation required to meet North American lateral drift limits. • Experiments on pre-engineered timber and timber-steel beam-column connections conducted under combined shear and cyclic rotation. • Influence of connection type, gravity loading, screw configuration, and multiple connectors placed side-by-side studied. • Interlocking jaw (Megant 430 ×150) and bolt and collar (Ricon 390 ×80) achieved maximum rotations beyond 0.06 rad. • Placing multiple bolt and collar connectors side-by-side on the beam/column face does not influence rotation capacity. • Welded bolt and collar connections achieved significant rotation capacities (>0.07 rad) but depends on weld configuration.

Engineering StructuresVol. 347
Queen's University (CA)
Openalex Percentile: Top 19%
Wood Treatment and Properties
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.