A geometric insight into ECG classification: leveraging phase space reconstruction and distance to measure

We propose a geometric framework for robust ECG classification by combining phase space reconstruction (PSR) and the distance-to-measure (DTM) function to capture intrinsic cardiac dynamics. One-dimensional ECG signals are embedded into high-dimensional phase spaces, forming point clouds that reflect rhythm characteristics. Using median-of-means kernel density estimation, we identify high-density regions and construct DTM-based pseudo-distances, enhancing noise resilience and discriminative power. Evaluated on MIT-BIH and PTB datasets, our method achieves 89.08% accuracy with logistic regression and 91.42% with Gradient Boosting Trees under Gaussian noise. DTM features complement traditional statistical ones, demonstrating strong potential for nonlinear, interpretable, and noise-robust ECG analysis.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-11-11
DOI
https://doi.org/10.1080/10255842.2025.2582763
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A geometric insight into ECG classification: leveraging phase space reconstruction and distance to measure

Junbin Zang, Xinlong Yang, Chenyang Xue, Zhidong Zhang et al.
Computer Methods in Biomechanics & Biomedical Engineering
ECG Monitoring and Analysis
article

A geometric insight into ECG classification: leveraging phase space reconstruction and distance to measure

Junbin Zang, Xinlong Yang, Chenyang Xue, Zhidong Zhang, Tianming Cai
article en

Abstract

We propose a geometric framework for robust ECG classification by combining phase space reconstruction (PSR) and the distance-to-measure (DTM) function to capture intrinsic cardiac dynamics. One-dimensional ECG signals are embedded into high-dimensional phase spaces, forming point clouds that reflect rhythm characteristics. Using median-of-means kernel density estimation, we identify high-density regions and construct DTM-based pseudo-distances, enhancing noise resilience and discriminative power. Evaluated on MIT-BIH and PTB datasets, our method achieves 89.08% accuracy with logistic regression and 91.42% with Gradient Boosting Trees under Gaussian noise. DTM features complement traditional statistical ones, demonstrating strong potential for nonlinear, interpretable, and noise-robust ECG analysis.

Computer Methods in Biomechanics & Biomedical Engineering
North University of China (CN), Shanxi University (CN), Integrated Optoelectronics (Norway) (NO), Shanxi Science and Technology Department (CN)
Openalex Percentile: Top 49%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.