BackgroundIntravenous infusion often faces difficulties in patients with obesity, aging, or dark skin. Low-cost vein detection using near-infrared (NIR) light is gaining attention to improve vascular access. Previous studies focused mainly on high-end devices or single algorithm performance.ObjectiveThis study aimed to develop a low-cost vein detection system using 850 nm NIR LEDs and Raspberry Pi 4. It also sought to evaluate and compare multiple image enhancement algorithms. Performance was assessed using Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM) metrics.MethodsThe device consisted of an NIR LED module, IR-sensitive camera, and Raspberry Pi 4. Algorithms used were Contrast Limited Adaptive Histogram Equalization (CLAHE), Unsharp Masking, Median Filter, and Fuzzy Adaptive Gamma. Images from 13 subjects were enhanced and evaluated using three quantitative metrics.ResultsUnsharp Masking achieved the lowest MSE (36.17) and highest PSNR (32.98), showing strong contrast enhancement. Median Filtering produced the highest SSIM (0.926), effectively preserving structural consistency. Combining CLAHE + Unsharp Masking + Median Filter yielded the best overall performance. However, this combination led to a slight SSIM decrease due to over-enhancement and edge distortion. Hardware limitations (low resolution and processing speed of Raspberry Pi 4) also impacted image quality and SSIM.ConclusionThe proposed low-cost vein detection system effectively enhanced vascular images using selected algorithms. Unsharp Masking and Median Filtering were particularly effective in improving contrast and maintaining structure. Future work should focus on real-time optimization and hardware upgrades to improve clinical applicability.

Authors

Institutions

Publication Details

Journal
Technology and Health Care
Published
2025-11-11
DOI
https://doi.org/10.1177/09287329251389493
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A study on image processing of vein extraction images according to development of vein detector

Jin-Hyoung Jeong, Seung-Hun Kim, Sung-Kee Bang
Technology and Health Care
Central Venous Catheters and Hemodialysis
article

A study on image processing of vein extraction images according to development of vein detector

Jin-Hyoung Jeong, Seung-Hun Kim, Sung-Kee Bang
article en

Abstract

BackgroundIntravenous infusion often faces difficulties in patients with obesity, aging, or dark skin. Low-cost vein detection using near-infrared (NIR) light is gaining attention to improve vascular access. Previous studies focused mainly on high-end devices or single algorithm performance.ObjectiveThis study aimed to develop a low-cost vein detection system using 850 nm NIR LEDs and Raspberry Pi 4. It also sought to evaluate and compare multiple image enhancement algorithms. Performance was assessed using Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM) metrics.MethodsThe device consisted of an NIR LED module, IR-sensitive camera, and Raspberry Pi 4. Algorithms used were Contrast Limited Adaptive Histogram Equalization (CLAHE), Unsharp Masking, Median Filter, and Fuzzy Adaptive Gamma. Images from 13 subjects were enhanced and evaluated using three quantitative metrics.ResultsUnsharp Masking achieved the lowest MSE (36.17) and highest PSNR (32.98), showing strong contrast enhancement. Median Filtering produced the highest SSIM (0.926), effectively preserving structural consistency. Combining CLAHE + Unsharp Masking + Median Filter yielded the best overall performance. However, this combination led to a slight SSIM decrease due to over-enhancement and edge distortion. Hardware limitations (low resolution and processing speed of Raspberry Pi 4) also impacted image quality and SSIM.ConclusionThe proposed low-cost vein detection system effectively enhanced vascular images using selected algorithms. Unsharp Masking and Median Filtering were particularly effective in improving contrast and maintaining structure. Future work should focus on real-time optimization and hardware upgrades to improve clinical applicability.

Technology and Health Care
Sogang University (KR), Catholic Kwandong University (KR)
Openalex Percentile: Top 49%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A study on image processing of vein extraction images according to development of vein detector — Jin-Hyoung Jeong, Seung-Hun Kim, et al. · Technology and Health Care (2025) | TGRS Research Map | TGRS