Physics-informed sinogram completion for metal artifact reduction in non-contrast brain CT images with neurovascular coils: comparison with traditional and deep learning-based methods

Abstract Backgroud Metal artifacts from neurovascular coil affect image quality in computed tomography (CT), we aim to use Physics-informed sinogram completion (PISC) to reduce metal artifacts, and compare with two traditional metal artifact reduction (MAR) methods -- Normalized MAR (NMAR), Metal Artifact Reduction for Orthopedic Implants (O-MAR) and two deep learning (DL) based methods -- convolutional neural network based metal artifact reduction (CNN-MAR) and dual domain network (DuDoNet). Methods 40 consecutive patients who underwent endovascular coil embolization for intracranial aneurysms between July 2021 to December 2022 were included, all of whom underwent brain CT examinations. Above methods were compared quantitatively by calculating the artifact index (AI). Two blinded radiologists independently evaluated these MAR methods using a five-point scale, assessing metal artifact severity and diagnose confidence, resolution, new artifacts and the contours of different soft tissue interfaces. Friedman M test was used for quantitative and qualitative evaluation. Results The AI value were significantly lower in DuDoNet images when compared with FBP, NMAR, O-MAR, CNN-MAR images (p < 0.001), although no statistically significant when compared with PISC images (p = 0.181). For metal artifact severity and diagnosis confidence score, PISC method was significantly higher than FBP, NMAR, O-MAR and DuDoNet methods (all p < 0.05), although no statistically significant when compared with CNN-MAR method (p = 1.000). The resolution and contours of different soft tissue interfaces score were lower in DuDoNet images when compared with other images (all p < 0.001). The PISC method introduces the least new artifacts among these MAR methods. In addition, using traditional or DL based methods, we found new lesion obscured by metal artifacts in two cases. Conclusions For quantitative image analysis, DuDoNet achieved the best image quality. For qualitative image analysis, PISC achieved the best image quality. DuDoNet method can cause over-smoothing and blurring effect. PISC method introduce least new artifact.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2025-11-11
DOI
https://doi.org/10.1186/s12880-025-01972-y
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physics-informed sinogram completion for metal artifact reduction in non-contrast brain CT images with neurovascular coils: comparison with traditional and deep learning-based methods

Xinran Yan, Jianbin Zhu, Andong Ma, Jianhua Ma et al.
BMC Medical Imaging
Advanced X-ray and CT Imaging
article

Physics-informed sinogram completion for metal artifact reduction in non-contrast brain CT images with neurovascular coils: comparison with traditional and deep learning-based methods

Xinran Yan, Jianbin Zhu, Andong Ma, Jianhua Ma, Zhibo Wen, Zhuo Yu, Mingjun Lu, Zhijian Yu, Yuxin Li, Yi Guo, Chengyan Huang, Yaoming Qu
article en

Abstract

Abstract Backgroud Metal artifacts from neurovascular coil affect image quality in computed tomography (CT), we aim to use Physics-informed sinogram completion (PISC) to reduce metal artifacts, and compare with two traditional metal artifact reduction (MAR) methods -- Normalized MAR (NMAR), Metal Artifact Reduction for Orthopedic Implants (O-MAR) and two deep learning (DL) based methods -- convolutional neural network based metal artifact reduction (CNN-MAR) and dual domain network (DuDoNet). Methods 40 consecutive patients who underwent endovascular coil embolization for intracranial aneurysms between July 2021 to December 2022 were included, all of whom underwent brain CT examinations. Above methods were compared quantitatively by calculating the artifact index (AI). Two blinded radiologists independently evaluated these MAR methods using a five-point scale, assessing metal artifact severity and diagnose confidence, resolution, new artifacts and the contours of different soft tissue interfaces. Friedman M test was used for quantitative and qualitative evaluation. Results The AI value were significantly lower in DuDoNet images when compared with FBP, NMAR, O-MAR, CNN-MAR images (p < 0.001), although no statistically significant when compared with PISC images (p = 0.181). For metal artifact severity and diagnosis confidence score, PISC method was significantly higher than FBP, NMAR, O-MAR and DuDoNet methods (all p < 0.05), although no statistically significant when compared with CNN-MAR method (p = 1.000). The resolution and contours of different soft tissue interfaces score were lower in DuDoNet images when compared with other images (all p < 0.001). The PISC method introduces the least new artifacts among these MAR methods. In addition, using traditional or DL based methods, we found new lesion obscured by metal artifacts in two cases. Conclusions For quantitative image analysis, DuDoNet achieved the best image quality. For qualitative image analysis, PISC achieved the best image quality. DuDoNet method can cause over-smoothing and blurring effect. PISC method introduce least new artifact.

BMC Medical ImagingVol. 25(1)
Ji Hua Laboratory (CN), Zhujiang Hospital (CN), Southern Medical University (CN)
Openalex Percentile: Top 67%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.