Effect of Coloading Ringer Lactate on Blood Pressure Stability in Patients with Spinal Anesthesia

Background: The most common hemodynamic complication associated with spinal anesthesia is hypotension, hence the need for fluid coloading.Objective: The purpose of this study was to determine the effect of lactated ringer coloading fluid on blood pressure stability.Methods: This study was conducted using a quantitative method with a quasi-experimental design with a one-group pretest-posttest design. This study was conducted at X Hospital in the West Java region from March to April 2024. The research was carried out in the operating room after spinal anesthesia and after the administration of Ringer's lactate. The research instrument used an initial blood pressure observation sheet, blood pressure after spinal anesthesia, and after giving lactated ringer coloading with a calculation of 10 cc/kg of patient weight. The population in this study was all patients who underwent spinal anesthesia, and the sample of this study amounted to 60 patients with non non-probability sampling technique with purposive sampling. Data analysis in this study used univariate and bivariate analysis. This study has carried out data normality tests and research ethics. Bivariate analysis in this study used a Paired t-test.Results: The results showed that after spinal anesthesia, most (51.7%) patients had hypotension. After being given lactated ringer coloading, most patients (68.3%) had normal blood pressure. Systolic blood pressure increased by 9,750 mmHg, and diastolic also increased by 6,500 mmHg.Conclusion: This study concludes that lactated ringer coloading has a significant effect on both systolic and diastolic blood pressure stability after spinal anesthesia.

Authors

Institutions

Publication Details

Journal
JAI (Jurnal Anestesiologi Indonesia)
Published
2025-08-25
DOI
https://doi.org/10.14710/jai.v0i0.68598
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Coloading Ringer Lactate on Blood Pressure Stability in Patients with Spinal Anesthesia

Cici Valiani, Richa Noprianty, Muhammad Dwi Satriyanto, Togi Riki Rikardo Sijabat
JAI (Jurnal Anestesiologi Indonesia)
Hemodynamic Monitoring and Therapy
article

Effect of Coloading Ringer Lactate on Blood Pressure Stability in Patients with Spinal Anesthesia

Cici Valiani, Richa Noprianty, Muhammad Dwi Satriyanto, Togi Riki Rikardo Sijabat
article en

Abstract

Background: The most common hemodynamic complication associated with spinal anesthesia is hypotension, hence the need for fluid coloading.Objective: The purpose of this study was to determine the effect of lactated ringer coloading fluid on blood pressure stability.Methods: This study was conducted using a quantitative method with a quasi-experimental design with a one-group pretest-posttest design. This study was conducted at X Hospital in the West Java region from March to April 2024. The research was carried out in the operating room after spinal anesthesia and after the administration of Ringer's lactate. The research instrument used an initial blood pressure observation sheet, blood pressure after spinal anesthesia, and after giving lactated ringer coloading with a calculation of 10 cc/kg of patient weight. The population in this study was all patients who underwent spinal anesthesia, and the sample of this study amounted to 60 patients with non non-probability sampling technique with purposive sampling. Data analysis in this study used univariate and bivariate analysis. This study has carried out data normality tests and research ethics. Bivariate analysis in this study used a Paired t-test.Results: The results showed that after spinal anesthesia, most (51.7%) patients had hypotension. After being given lactated ringer coloading, most patients (68.3%) had normal blood pressure. Systolic blood pressure increased by 9,750 mmHg, and diastolic also increased by 6,500 mmHg.Conclusion: This study concludes that lactated ringer coloading has a significant effect on both systolic and diastolic blood pressure stability after spinal anesthesia.

JAI (Jurnal Anestesiologi Indonesia)Vol. 17(3)
Universitas Abdurrab (ID), Islamic University of Riau (ID), Panca Bhakti University (ID), Riau University (ID)
Openalex Percentile: Top 48%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Coloading Ringer Lactate on Blood Pressure Stability in Patients with Spinal Anesthesia — Cici Valiani, Richa Noprianty, et al. · JAI (Jurnal Anestesiologi Indonesia) (2025) | TGRS Research Map | TGRS