Evolution of Analytical Methods for the Determination of Ethanol in Blood and Breath for Clinical and Forensic Purposes

ABSTRACT Laboratory procedures for measuring the concentration of alcohol (ethanol) in blood and other body fluids have been available for more than 100 years. The person's blood alcohol concentration (BAC) provides important information to confirm clinical signs and symptoms of drunkenness. Analysis of blood samples required separation of ethanol from the biological matrix by diffusion or distillation before oxidation with chromic acid and titrimetric analysis. By the 1950s enzymatic oxidation became possible after alcohol dehydrogenase (ADH) was extracted and purified from horse liver or yeast. The ADH method furnished a more sensitive and specific method of analysis and laboratory procedures could also be automated. The Breathalyzer instrument was developed in the 1950s and used as a surrogate for measuring the BAC directly. By the 1960s, gas–liquid chromatography (GLC) with flame ionization detector (FID) became the method of choice for analysis of ethanol and other volatiles for forensic purposes. After dilution of the blood sample with internal standard, direct injection and/or headspace (HS) sampling techniques were used. More recently, GC separations are combined with mass spectrometric (MS) detection, which permits more unequivocal identification of ethanol from its characteristic mass fragmentation pattern. Modern technology for breath‐alcohol analysis uses infrared spectrometry and/or electrochemical oxidation for the determination of ethanol. This article gives a retrospective account of major developments in methodology for the determination of ethanol in blood and breath for clinical and forensic purposes and pays homage to some of the pioneers in this domain of analytical toxicology. This article is categorized under: Toxicology > Alcohol Toxicology > Analytical Toxicology > Drug‐Impaired Driving

Authors

Institutions

Publication Details

Journal
Wiley Interdisciplinary Reviews Forensic Science
Published
2025-11-10
DOI
https://doi.org/10.1002/wfs2.70018
Citations
1
Primary Topic
Alcohol Consumption and Health Effects
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evolution of Analytical Methods for the Determination of Ethanol in Blood and Breath for Clinical and Forensic Purposes

Alan Wayne Jones
1 citations
Wiley Interdisciplinary Reviews Forensic Science
Alcohol Consumption and Health Effects
1.47
article

Evolution of Analytical Methods for the Determination of Ethanol in Blood and Breath for Clinical and Forensic Purposes

Alan Wayne Jones
article en
1 citations

Abstract

ABSTRACT Laboratory procedures for measuring the concentration of alcohol (ethanol) in blood and other body fluids have been available for more than 100 years. The person's blood alcohol concentration (BAC) provides important information to confirm clinical signs and symptoms of drunkenness. Analysis of blood samples required separation of ethanol from the biological matrix by diffusion or distillation before oxidation with chromic acid and titrimetric analysis. By the 1950s enzymatic oxidation became possible after alcohol dehydrogenase (ADH) was extracted and purified from horse liver or yeast. The ADH method furnished a more sensitive and specific method of analysis and laboratory procedures could also be automated. The Breathalyzer instrument was developed in the 1950s and used as a surrogate for measuring the BAC directly. By the 1960s, gas–liquid chromatography (GLC) with flame ionization detector (FID) became the method of choice for analysis of ethanol and other volatiles for forensic purposes. After dilution of the blood sample with internal standard, direct injection and/or headspace (HS) sampling techniques were used. More recently, GC separations are combined with mass spectrometric (MS) detection, which permits more unequivocal identification of ethanol from its characteristic mass fragmentation pattern. Modern technology for breath‐alcohol analysis uses infrared spectrometry and/or electrochemical oxidation for the determination of ethanol. This article gives a retrospective account of major developments in methodology for the determination of ethanol in blood and breath for clinical and forensic purposes and pays homage to some of the pioneers in this domain of analytical toxicology. This article is categorized under: Toxicology > Alcohol Toxicology > Analytical Toxicology > Drug‐Impaired Driving

Wiley Interdisciplinary Reviews Forensic ScienceVol. 7(4)
Linköping University (SE)
Openalex Percentile: Top 14%
Alcohol Consumption and Health Effects
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evolution of Analytical Methods for the Determination of Ethanol in Blood and Breath for Clinical and Forensic Purposes — Alan Wayne Jones · Wiley Interdisciplinary Reviews Forensic Science (2025) | TGRS Research Map | TGRS