Corneal viscoelasticity is associated with intraocular pressure under physiological baseline: insights from the rheological properties of corneal lenticules

This study aims to investigate the modulation effect of baseline intraocular pressure (IOP) on corneal viscoelastic modulus within physiological ranges. We collected 48 stromal lenticules from 26 healthy myopic patients undergoing SMILE surgery. Based on biomechanically corrected IOP (bIOP), stratifying the samples into a low-pressure group (bIOP <15 mmHg, n = 15) and a high-pressure group (bIOP ≥15 mmHg, n = 33) according to pre-operative measurements. Each fresh lenticule underwent strain-controlled torsional rheometry at 37 °C (shear strain 1%, angular frequency 0.1-100 rad s<sup>-1</sup>), recording storage modulus (<i>G'</i>), loss modulus (<i>G″</i>), complex viscosity (<i>η*</i>), and loss factor (tan <i>δ</i>), with elastic modulus (<i>E</i>) calculated from G'. In parallel, <i>in vivo</i> corneal deformation and stiffness parameters were obtained using the Corvis ST. The results showed that viscoelastic parameters increased monotonically with frequency, demonstrating solid-like behavior; in the frequency range of 10<sup>0</sup>-10<sup>1.5</sup> rad s<sup>-1</sup>, <i>G'</i> and <i>E</i> were significantly higher in the high-pressure group compared to the low-pressure group (both <i>p</i> < 0.05), while the log-modulus versus log-frequency slopes showed no significant difference, indicating an upward "stiffness offset" due to elevated bIOP without altering dispersive characteristics. Corvis ST also confirmed that the high-pressure group exhibited smaller deformation amplitudes and higher stiffness parameters. Overall, even within the normal range, elevated baseline IOP results in an upward shift in corneal <i>E</i> without affecting its time-dependent properties, suggesting that corneal stromal rigidity is adaptable to the ocular pressure environment under physiological conditions.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2025-11-11
DOI
https://doi.org/10.3389/fbioe.2025.1694568
Citations
1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corneal viscoelasticity is associated with intraocular pressure under physiological baseline: insights from the rheological properties of corneal lenticules

Qi Ren, Xiaonan Yang, Xiangbin Kong, Peng Su et al.
1 citations
Frontiers in Bioengineering and Biotechnology
Corneal surgery and disorders
1.36
article

Corneal viscoelasticity is associated with intraocular pressure under physiological baseline: insights from the rheological properties of corneal lenticules

Qi Ren, Xiaonan Yang, Xiangbin Kong, Peng Su, Quan Liu, Chang Liu, Pengxia Wan
article en
1 citations

Abstract

This study aims to investigate the modulation effect of baseline intraocular pressure (IOP) on corneal viscoelastic modulus within physiological ranges. We collected 48 stromal lenticules from 26 healthy myopic patients undergoing SMILE surgery. Based on biomechanically corrected IOP (bIOP), stratifying the samples into a low-pressure group (bIOP <15 mmHg, n = 15) and a high-pressure group (bIOP ≥15 mmHg, n = 33) according to pre-operative measurements. Each fresh lenticule underwent strain-controlled torsional rheometry at 37 °C (shear strain 1%, angular frequency 0.1-100 rad s<sup>-1</sup>), recording storage modulus (<i>G'</i>), loss modulus (<i>G″</i>), complex viscosity (<i>η*</i>), and loss factor (tan <i>δ</i>), with elastic modulus (<i>E</i>) calculated from G'. In parallel, <i>in vivo</i> corneal deformation and stiffness parameters were obtained using the Corvis ST. The results showed that viscoelastic parameters increased monotonically with frequency, demonstrating solid-like behavior; in the frequency range of 10<sup>0</sup>-10<sup>1.5</sup> rad s<sup>-1</sup>, <i>G'</i> and <i>E</i> were significantly higher in the high-pressure group compared to the low-pressure group (both <i>p</i> < 0.05), while the log-modulus versus log-frequency slopes showed no significant difference, indicating an upward "stiffness offset" due to elevated bIOP without altering dispersive characteristics. Corvis ST also confirmed that the high-pressure group exhibited smaller deformation amplitudes and higher stiffness parameters. Overall, even within the normal range, elevated baseline IOP results in an upward shift in corneal <i>E</i> without affecting its time-dependent properties, suggesting that corneal stromal rigidity is adaptable to the ocular pressure environment under physiological conditions.

Frontiers in Bioengineering and BiotechnologyVol. 13
Sun Yat-sen University (CN), The First Affiliated Hospital, Sun Yat-sen University (CN), Foshan Second People's Hospital (CN), Guangzhou Eighth People's Hospital (CN)
Openalex Percentile: Top 14%
Corneal surgery and disorders
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.