Surface‐Defect Engineered Benzothiazole Nanoparticles for Amplified Electrochemiluminescence: Monitoring Charge Transfer Kinetics and Ultrasensitive Biosensing

Abstract Benzothiazole derivatives hold promise for electrochemiluminescence (ECL) due to their unique physicochemical properties. However, their reliance on metal complexes in existing systems significantly restricts their biocompatibility and potential biomedical applications. This study pioneers a precisely engineered, metal‐free donor–acceptor (D–A) architecture, leveraging benzothiazole as the electron‐accepting moiety. Through the rational modulation of electron‐withdrawing ability and conjugation length via tailored functionalization, a novel series of aggregation‐induced electrochemiluminescent (AIECL) emitters are developed that are intrinsically compatible with aqueous biological media. Among these, engineered nanoparticles derived from carbazole‐benzothiadiazole derivatives (BTZ‐PCz NPs) with incorporated surface defects demonstrated superior ECL performance. Critically, scanning electrochemical microscopy (SECM) is employed to quantitatively analyze charge transfer dynamics in surface‐defect emitters, providing unambiguous evidence for the defect‐mediated charge transport processes that drive ECL enhancement. Moreover, capitalizing on the superior aqueous ECL properties of BTZ‐PCz NPs, a highly sensitive and label‐free detection platform for amyloid‐β42 (Aβ42), a pivotal biomarker of Alzheimer's disease, is developed. This work not only expands the library of efficient, water‐compatible AIECL materials by introducing benzothiazole‐based D–A systems, but more significantly, pioneers the application of SECM in quantifying surface defect‐enhanced ECL, thereby bridging the gap between material surface properties and ECL performance.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2025-11-10
DOI
https://doi.org/10.1002/adfm.202520860
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface‐Defect Engineered Benzothiazole Nanoparticles for Amplified Electrochemiluminescence: Monitoring Charge Transfer Kinetics and Ultrasensitive Biosensing

Peiyao Du, Hongjie Song, Hui Xiao, Yaorong He et al.
2 citations
Advanced Functional Materials
Advanced biosensing and bioanalysis techniques
1.61
article

Surface‐Defect Engineered Benzothiazole Nanoparticles for Amplified Electrochemiluminescence: Monitoring Charge Transfer Kinetics and Ultrasensitive Biosensing

Peiyao Du, Hongjie Song, Hui Xiao, Yaorong He, Zhengang Han, Shuying Li, Xiaoquan Lu, Shaoyu Zou, Meluze Luobu
article en
2 citations

Abstract

Abstract Benzothiazole derivatives hold promise for electrochemiluminescence (ECL) due to their unique physicochemical properties. However, their reliance on metal complexes in existing systems significantly restricts their biocompatibility and potential biomedical applications. This study pioneers a precisely engineered, metal‐free donor–acceptor (D–A) architecture, leveraging benzothiazole as the electron‐accepting moiety. Through the rational modulation of electron‐withdrawing ability and conjugation length via tailored functionalization, a novel series of aggregation‐induced electrochemiluminescent (AIECL) emitters are developed that are intrinsically compatible with aqueous biological media. Among these, engineered nanoparticles derived from carbazole‐benzothiadiazole derivatives (BTZ‐PCz NPs) with incorporated surface defects demonstrated superior ECL performance. Critically, scanning electrochemical microscopy (SECM) is employed to quantitatively analyze charge transfer dynamics in surface‐defect emitters, providing unambiguous evidence for the defect‐mediated charge transport processes that drive ECL enhancement. Moreover, capitalizing on the superior aqueous ECL properties of BTZ‐PCz NPs, a highly sensitive and label‐free detection platform for amyloid‐β42 (Aβ42), a pivotal biomarker of Alzheimer's disease, is developed. This work not only expands the library of efficient, water‐compatible AIECL materials by introducing benzothiazole‐based D–A systems, but more significantly, pioneers the application of SECM in quantifying surface defect‐enhanced ECL, thereby bridging the gap between material surface properties and ECL performance.

Advanced Functional MaterialsVol. 36(23)
Northwest Normal University (CN), Xi'an Jiaotong University (CN), Northwest A&F University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 14%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.