Investigation of airborne transmission and thermal comfort in a train cabin: Effects of air change rate and supply mode

Developing ventilation strategies that balance protection, comfort, and well-being is crucial for efficient train operations and enhanced passenger experience. Although raising the Air Change per Hour (ACH) can mitigate bioaerosol transmission, it may induce undesirable airflow disturbances and increase energy consumption. To elucidate the roles of ACH and large-scale airflow patterns, a three-dimensional computational fluid dynamics (CFD) model based on the Eulerian-Lagrangian approach is established. The study investigates the impacts of particle size, ventilation configuration, and airflow velocity on the cabin environment. Results indicate that simply intensifying ventilation does not consistently reduce aerosol deposition on passengers due to the asymmetric arrangement of seats and vents. Excessive ventilation (24 ACH) demonstrates clear diminishing returns in performance, whereas inadequate ventilation (6 ACH) significantly elevates aerosol concentration and infection risk. Compared with merely boosting the ventilation rate, optimizing the supply layout is more effective for achieving a safe and comfortable environment. At 12 ACH, the sidewall air supply mode outperforms the top air supply mode in controlling aerosol deposition on passengers, while lowering the airflow non-uniformity index by 20.0% and the draught rate ( ) in the breathing zone by 32.1%. These findings provide guidance for improving train cabin ventilation toward coordinated management of infection control, comfort, and energy utilization.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-11-11
DOI
https://doi.org/10.1016/j.csite.2025.107387
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of airborne transmission and thermal comfort in a train cabin: Effects of air change rate and supply mode

Zhou Huang, Renze Xu, Xiaowang Pan, Fan Wu et al.
1 citations
Case Studies in Thermal Engineering
Infection Control and Ventilation
1.52
article

Investigation of airborne transmission and thermal comfort in a train cabin: Effects of air change rate and supply mode

Zhou Huang, Renze Xu, Xiaowang Pan, Fan Wu, Lian Shen, Jianci Yu, Yongda Huang
article en
1 citations

Abstract

Developing ventilation strategies that balance protection, comfort, and well-being is crucial for efficient train operations and enhanced passenger experience. Although raising the Air Change per Hour (ACH) can mitigate bioaerosol transmission, it may induce undesirable airflow disturbances and increase energy consumption. To elucidate the roles of ACH and large-scale airflow patterns, a three-dimensional computational fluid dynamics (CFD) model based on the Eulerian-Lagrangian approach is established. The study investigates the impacts of particle size, ventilation configuration, and airflow velocity on the cabin environment. Results indicate that simply intensifying ventilation does not consistently reduce aerosol deposition on passengers due to the asymmetric arrangement of seats and vents. Excessive ventilation (24 ACH) demonstrates clear diminishing returns in performance, whereas inadequate ventilation (6 ACH) significantly elevates aerosol concentration and infection risk. Compared with merely boosting the ventilation rate, optimizing the supply layout is more effective for achieving a safe and comfortable environment. At 12 ACH, the sidewall air supply mode outperforms the top air supply mode in controlling aerosol deposition on passengers, while lowering the airflow non-uniformity index by 20.0% and the draught rate ( ) in the breathing zone by 32.1%. These findings provide guidance for improving train cabin ventilation toward coordinated management of infection control, comfort, and energy utilization.

Case Studies in Thermal EngineeringVol. 76
Central South University (CN), Changsha University (CN)
Openalex Percentile: Top 13%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.