Safe Torque-Off Technique for Fault Response in Dynamo Load Inverter

This paper proposes a Safe Torque Off (STO) technique for fault response in high-speed dynamometer systems. In such systems, the test motor and dynamo motor are mechanically coupled, and STO operation during a fault critically affects safety. When PWM is turned off, the inverter acts as a diode rectifier, and the motor’s back-EMF induces regenerative braking. This can cause overvoltage in the DC-link capacitor, risking damage to power devices. Assuming the absence of a Discharge Unit (DCU), which is a circuit that actively dissipates regenerative energy during emergency stops, we derive an energy-based equation to predict the capacitor voltage considering motor inertia, speed, and load torque. Using this result, a criterion is proposed for determining safe STO regions under emergency stop conditions. Simulation and experimental results verify that the predicted voltage aligns well with measured values, confirming the algorithm’s effectiveness. The proposed method prevents capacitor failure and fault propagation, enhancing system reliability. Although the algorithm depends on motor and system parameters, it provides a mathematically grounded, safe fault response strategy for high-performance drives.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-11-11
DOI
https://doi.org/10.5370/kiee.2025.74.11.1899
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safe Torque-Off Technique for Fault Response in Dynamo Load Inverter

Su-Hyeon Kim, Bon-Gwan Gu
The Transactions of The Korean Institute of Electrical Engineers
Electromagnetic Compatibility and Noise Suppression
article

Safe Torque-Off Technique for Fault Response in Dynamo Load Inverter

Su-Hyeon Kim, Bon-Gwan Gu
article en

Abstract

This paper proposes a Safe Torque Off (STO) technique for fault response in high-speed dynamometer systems. In such systems, the test motor and dynamo motor are mechanically coupled, and STO operation during a fault critically affects safety. When PWM is turned off, the inverter acts as a diode rectifier, and the motor’s back-EMF induces regenerative braking. This can cause overvoltage in the DC-link capacitor, risking damage to power devices. Assuming the absence of a Discharge Unit (DCU), which is a circuit that actively dissipates regenerative energy during emergency stops, we derive an energy-based equation to predict the capacitor voltage considering motor inertia, speed, and load torque. Using this result, a criterion is proposed for determining safe STO regions under emergency stop conditions. Simulation and experimental results verify that the predicted voltage aligns well with measured values, confirming the algorithm’s effectiveness. The proposed method prevents capacitor failure and fault propagation, enhancing system reliability. Although the algorithm depends on motor and system parameters, it provides a mathematically grounded, safe fault response strategy for high-performance drives.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(11)
Openalex Percentile: Top 67%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Safe Torque-Off Technique for Fault Response in Dynamo Load Inverter — Su-Hyeon Kim, Bon-Gwan Gu · The Transactions of The Korean Institute of Electrical Engineers (2025) | TGRS Research Map | TGRS