Deep learning-based approach for accurate detection of fetal QRS complexes in abdominal ECG signals

Congenital heart defects are the leading cause of mortality related to birth defects, making early monitoring of fetal electrocardiogram (FECG) vital for the detection of abnormal fetal heart rate (FHR) patterns. Accurate fetal QRS complex detection in FECG is crucial for assessing fetal health, including heart rate and the early identification of congenital conditions. This study presents a novel automated framework using a one-dimensional Convolutional Neural Network (1D-CNN) to detect fetal QRS complexes from abdominal electrocardiogram (AECG) signals, sourced from the PhysioNet Non-Invasive FECG Database (NI-FECGDB). The proposed CNN architecture comprises five convolutional layers, seven batch normalization layers, three dropout layers, and three dense layers. In the initial phase to generate annotations tailored for the proposed network, each AECG signal was partitioned into overlapping 1-second windows, facilitating data augmentation. Binary annotations were generated for each 100-millisecond segment based on the presence or absence of fetal QRS complexes. Subsequently, after performing preprocessing steps, the developed algorithm was applied, and its performance was evaluated using metrics such as accuracy, mean squared error, F1-score, sensitivity, specificity, and precision. The results were compared with those from previous studies utilizing the NI-FECGDB database. The proposed lightweight 1D-CNN architecture demonstrated exceptional performance, achieving 96.79% accuracy, 97.91% sensitivity, 92.79% specificity and 97.88% precision while requiring only 20 AECG signals for training - a significant improvement over existing methods that typically demanded larger datasets. This framework's innovative design eliminated the need for maternal ECG component extraction, thereby reducing computational complexity and potential signal decomposition artifacts. The combination of a simplified five-layer architecture with our novel 100 ms resolution labeling strategy enabled high-precision fetal QRS detection while maintaining minimal preprocessing requirements. These advances position our method as a robust and efficient solution for clinical fetal monitoring applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-10
DOI
https://doi.org/10.1038/s41598-025-22999-9
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning-based approach for accurate detection of fetal QRS complexes in abdominal ECG signals

Hamed Danandeh Hesar, Kimia Esmaeili Alidash
1 citations
Scientific Reports
ECG Monitoring and Analysis
1.39
article

Deep learning-based approach for accurate detection of fetal QRS complexes in abdominal ECG signals

Hamed Danandeh Hesar, Kimia Esmaeili Alidash
article en
1 citations

Abstract

Congenital heart defects are the leading cause of mortality related to birth defects, making early monitoring of fetal electrocardiogram (FECG) vital for the detection of abnormal fetal heart rate (FHR) patterns. Accurate fetal QRS complex detection in FECG is crucial for assessing fetal health, including heart rate and the early identification of congenital conditions. This study presents a novel automated framework using a one-dimensional Convolutional Neural Network (1D-CNN) to detect fetal QRS complexes from abdominal electrocardiogram (AECG) signals, sourced from the PhysioNet Non-Invasive FECG Database (NI-FECGDB). The proposed CNN architecture comprises five convolutional layers, seven batch normalization layers, three dropout layers, and three dense layers. In the initial phase to generate annotations tailored for the proposed network, each AECG signal was partitioned into overlapping 1-second windows, facilitating data augmentation. Binary annotations were generated for each 100-millisecond segment based on the presence or absence of fetal QRS complexes. Subsequently, after performing preprocessing steps, the developed algorithm was applied, and its performance was evaluated using metrics such as accuracy, mean squared error, F1-score, sensitivity, specificity, and precision. The results were compared with those from previous studies utilizing the NI-FECGDB database. The proposed lightweight 1D-CNN architecture demonstrated exceptional performance, achieving 96.79% accuracy, 97.91% sensitivity, 92.79% specificity and 97.88% precision while requiring only 20 AECG signals for training - a significant improvement over existing methods that typically demanded larger datasets. This framework's innovative design eliminated the need for maternal ECG component extraction, thereby reducing computational complexity and potential signal decomposition artifacts. The combination of a simplified five-layer architecture with our novel 100 ms resolution labeling strategy enabled high-precision fetal QRS detection while maintaining minimal preprocessing requirements. These advances position our method as a robust and efficient solution for clinical fetal monitoring applications.

Scientific ReportsVol. 15(1)
Sahand University of Technology (IR)
Openalex Percentile: Top 13%
ECG Monitoring and Analysis
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.