Impact of sensor configuration and melanin concentration on reflective pulse oximetry using Monte Carlo simulations

We investigate the impact of melanin concentration C<sub>Mel</sub> and photoplethysmography (PPG) sensor configuration on signal quality and estimation accuracy of oxygen saturation [Formula: see text]. We deploy Monte Carlo (MC) simulations of photon-skin interactions to estimate arterial oxygen saturations [Formula: see text] ranging from 70 to 100% and melanin concentration C<sub>Mel</sub> ranging from 2.55 to 30.5%. We analysed the effects of red and infrared wavelengths (624 nm, 660 nm, 850 nm, and 940 nm), beam profiles (LED and VCSEL), as well as beam incidence angles of light sources (0°, 45°, and - 45°) on Perfusion Index (PI), reflective [Formula: see text] estimation, and signal-to-noise ratio (SNR) for source-detector distances ranging from 2 mm to 9 mm. Maximum PI was observed for in the red spectral range at 624 nm and in the infrared spectral range at 940 nm. In contrast, reflective pulse oximetry provided more accurate results at 660 nm and 850 nm, independent of wavelength combination. We conclude that the VCSEL beam profile at 0° is the optimal light source for a wide range of applications, as it offers a balance between PI and absolute [Formula: see text] estimations error.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-10
DOI
https://doi.org/10.1038/s41598-025-26560-6
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of sensor configuration and melanin concentration on reflective pulse oximetry using Monte Carlo simulations

Andreas Breidenassel, Maximilian Reiser, Oliver Amft
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Impact of sensor configuration and melanin concentration on reflective pulse oximetry using Monte Carlo simulations

Andreas Breidenassel, Maximilian Reiser, Oliver Amft
article en

Abstract

We investigate the impact of melanin concentration C<sub>Mel</sub> and photoplethysmography (PPG) sensor configuration on signal quality and estimation accuracy of oxygen saturation [Formula: see text]. We deploy Monte Carlo (MC) simulations of photon-skin interactions to estimate arterial oxygen saturations [Formula: see text] ranging from 70 to 100% and melanin concentration C<sub>Mel</sub> ranging from 2.55 to 30.5%. We analysed the effects of red and infrared wavelengths (624 nm, 660 nm, 850 nm, and 940 nm), beam profiles (LED and VCSEL), as well as beam incidence angles of light sources (0°, 45°, and - 45°) on Perfusion Index (PI), reflective [Formula: see text] estimation, and signal-to-noise ratio (SNR) for source-detector distances ranging from 2 mm to 9 mm. Maximum PI was observed for in the red spectral range at 624 nm and in the infrared spectral range at 940 nm. In contrast, reflective pulse oximetry provided more accurate results at 660 nm and 850 nm, independent of wavelength combination. We conclude that the VCSEL beam profile at 0° is the optimal light source for a wide range of applications, as it offers a balance between PI and absolute [Formula: see text] estimations error.

Scientific ReportsVol. 15(1)
University of Freiburg (DE), University of Applied Sciences Landshut (DE), Hahn-Schickard-Gesellschaft für angewandte Forschung (DE)
Openalex Percentile: Top 67%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of sensor configuration and melanin concentration on reflective pulse oximetry using Monte Carlo simulations — Andreas Breidenassel, Maximilian Reiser, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS