The sensitive and selective electrochemical detection of carcinoembryonic antigen using a nanoMIPs-aptamer sandwich assay

Carcinoembryonic antigen (CEA) is a well-established cancer biomarker that plays a crucial role in cancer diagnosis, treatment monitoring, and recurrence detection. This study presents the development of a highly sensitive and selective electrochemical sensor based on molecularly imprinted polymer nanoparticles (nanoMIPs) for CEA detection. CEA-specific nanoMIPs were synthesized and immobilized onto a screen-printed carbon electrode, providing selective recognition sites for CEA binding. The electrochemical signal probe was constructed using a metal organic framework, UiO-66-NH<sub>2</sub>, which served as the substrate for lead ion (Pb<sup>2+</sup>) adsorption and aptamer functionalization. A nanoMIPs-aptamer sandwich assay was used for CEA detection. Square wave anodic stripping voltammetry was used to measure the electrochemical response of Pb<sup>2+</sup>, which correlates with the amount of CEA captured on the electrode surface. The sensor demonstrated an excellent linear CEA detection range at concentrations between 1 and 1,000 ng/mL. The limit of detection was determined to be 1.4 ng/mL, which is below the clinical cut-off value for CEA. The proposed sandwich assay offers several advantages, including low cost, high sensitivity, good reproducibility, and excellent selectivity. When applied to CEA-spiked human serum samples with the appropriate pretreatment, the sensor achieved satisfactory recovery rates ranging from 98.12 to 103.24%, highlighting its applicability for clinical diagnostics.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-10
DOI
https://doi.org/10.1038/s41598-025-22971-7
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The sensitive and selective electrochemical detection of carcinoembryonic antigen using a nanoMIPs-aptamer sandwich assay

Kittitat Subannajui, Peter Wolschann, Yingyot Poo‐arporn, Rungtiva P. Poo-arporn et al.
1 citations
Scientific Reports
Advanced biosensing and bioanalysis techniques
0.81
article

The sensitive and selective electrochemical detection of carcinoembryonic antigen using a nanoMIPs-aptamer sandwich assay

Kittitat Subannajui, Peter Wolschann, Yingyot Poo‐arporn, Rungtiva P. Poo-arporn, Chutimon Akkapinyo, Peter A. Lieberzeit, Ramida Rattanakam
article en
1 citations

Abstract

Carcinoembryonic antigen (CEA) is a well-established cancer biomarker that plays a crucial role in cancer diagnosis, treatment monitoring, and recurrence detection. This study presents the development of a highly sensitive and selective electrochemical sensor based on molecularly imprinted polymer nanoparticles (nanoMIPs) for CEA detection. CEA-specific nanoMIPs were synthesized and immobilized onto a screen-printed carbon electrode, providing selective recognition sites for CEA binding. The electrochemical signal probe was constructed using a metal organic framework, UiO-66-NH<sub>2</sub>, which served as the substrate for lead ion (Pb<sup>2+</sup>) adsorption and aptamer functionalization. A nanoMIPs-aptamer sandwich assay was used for CEA detection. Square wave anodic stripping voltammetry was used to measure the electrochemical response of Pb<sup>2+</sup>, which correlates with the amount of CEA captured on the electrode surface. The sensor demonstrated an excellent linear CEA detection range at concentrations between 1 and 1,000 ng/mL. The limit of detection was determined to be 1.4 ng/mL, which is below the clinical cut-off value for CEA. The proposed sandwich assay offers several advantages, including low cost, high sensitivity, good reproducibility, and excellent selectivity. When applied to CEA-spiked human serum samples with the appropriate pretreatment, the sensor achieved satisfactory recovery rates ranging from 98.12 to 103.24%, highlighting its applicability for clinical diagnostics.

Scientific ReportsVol. 15(1)
University of Vienna (AT), Kasetsart University (TH), Mahidol University (TH), Synchrotron Light Research Institute (TH), King Mongkut's University of Technology Thonburi (TH)
ASEAN-European Academic University Network, Universität Wien, National Research Council of Thailand, King Mongkut's University of Technology Thonburi, Thailand Science Research and Innovation
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.