Fixed-Time Active Disturbance Rejection Control Scheme for Hybrid Energy Storage System Based on Cascaded Extended State Observer

To suppress the bus voltage fluctuations caused by disturbances such as photovoltaic-side power fluctuations and load-side power variations in hybrid energy storage systems, a fixed-time active disturbance rejection controller (FxADRC) integrated with a cascaded extended state observer (CESO) is proposed in this paper. The paper first constructs a dynamic model of the hybrid energy storage system, considering the impact of disturbances. Second, this paper designs a cascaded extended state observer to estimate the total disturbances affecting the system, achieving finite-time convergence performance. Then, a fixed-time sliding mode active disturbance rejection control strategy combined with the CESO is proposed, which can achieve bus voltage tracking with fixed-time convergence rate irrespective of the effect of the initial state. In addition, the stability of the proposed controller is validated by the Lyapunov method. Finally, Comparative studies are conducted by simulation to verify the effectiveness and outstanding performance of the proposed control scheme.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-11-10
DOI
https://doi.org/10.3390/en18225917
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fixed-Time Active Disturbance Rejection Control Scheme for Hybrid Energy Storage System Based on Cascaded Extended State Observer

Junmei Zhao, Yifeng Ren, Kai Zhang, Rui Kang
Energies
Microgrid Control and Optimization
article

Fixed-Time Active Disturbance Rejection Control Scheme for Hybrid Energy Storage System Based on Cascaded Extended State Observer

Junmei Zhao, Yifeng Ren, Kai Zhang, Rui Kang
article en

Abstract

To suppress the bus voltage fluctuations caused by disturbances such as photovoltaic-side power fluctuations and load-side power variations in hybrid energy storage systems, a fixed-time active disturbance rejection controller (FxADRC) integrated with a cascaded extended state observer (CESO) is proposed in this paper. The paper first constructs a dynamic model of the hybrid energy storage system, considering the impact of disturbances. Second, this paper designs a cascaded extended state observer to estimate the total disturbances affecting the system, achieving finite-time convergence performance. Then, a fixed-time sliding mode active disturbance rejection control strategy combined with the CESO is proposed, which can achieve bus voltage tracking with fixed-time convergence rate irrespective of the effect of the initial state. In addition, the stability of the proposed controller is validated by the Lyapunov method. Finally, Comparative studies are conducted by simulation to verify the effectiveness and outstanding performance of the proposed control scheme.

EnergiesVol. 18(22)
North University of China (CN)
Openalex Percentile: Top 58%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fixed-Time Active Disturbance Rejection Control Scheme for Hybrid Energy Storage System Based on Cascaded Extended State Observer — Junmei Zhao, Yifeng Ren, et al. · Energies (2025) | TGRS Research Map | TGRS