Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration

Electrochemical immunosensors offer rapid, sensitive biomarker detection but typically rely on complex three- or two-electrode architectures with dedicated reference electrodes, complicating fabrication and miniaturization. Herein, we present an electrochemical immunosensor based on a diffusion-isolated, two-electrode system of micropatterned indium tin oxide (ITO) that eliminates the need for a separate reference electrode. A kinetically robust (fast, surface-insensitive) redox mediator [Os(bpy)<sub>2</sub>Cl<sub>2</sub><sup>+</sup>/Os(bpy)<sub>2</sub>Cl<sub>2</sub> (Os<sup>III</sup>/Os<sup>II</sup>)] simultaneously acts as the enzymatic substrate, the counterbalancing electroactive species, and the potential-guiding element, removing the requirement for additional electroactive species. Further, diaphorase (DI) is employed as the catalytic label in a sandwich-type immunosensor for prostate-specific antigen (PSA), rapidly reducing Os<sup>III</sup> to Os<sup>II</sup> in the presence of reduced nicotinamide adenine dinucleotide (NADH), enabling efficient electrochemical-enzymatic redox cycling involving the ITO electrode, Os<sup>III</sup>, DI, and NADH. By patterning the working and auxiliary electrodes 1.0 mm apart, we achieved diffusion isolation that prevents cross-talk between electrodes. After optimizing blocking, potential difference, and incubation conditions, the sensor achieved a detection limit of approximately 20 pg/mL and a detection range of 20-10 ng/mL in spiked human serum. The results of our analysis of clinical serum samples correlated closely with those of a commercial PSA assay, demonstrating both analytical accuracy and robustness. This study establishes a streamlined, point-of-care-compatible platform that achieves stable potential control and robust kinetics without a dedicated reference electrode.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-10
DOI
https://doi.org/10.1021/acssensors.5c02930
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration

Seonhwa Park, Haesik Yang, Youngsuk Kim, Jihyeon Kim et al.
2 citations
ACS Sensors
Advanced biosensing and bioanalysis techniques
1.61
article

Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration

Seonhwa Park, Haesik Yang, Youngsuk Kim, Jihyeon Kim, Subin Park
article en
2 citations

Abstract

Electrochemical immunosensors offer rapid, sensitive biomarker detection but typically rely on complex three- or two-electrode architectures with dedicated reference electrodes, complicating fabrication and miniaturization. Herein, we present an electrochemical immunosensor based on a diffusion-isolated, two-electrode system of micropatterned indium tin oxide (ITO) that eliminates the need for a separate reference electrode. A kinetically robust (fast, surface-insensitive) redox mediator [Os(bpy)<sub>2</sub>Cl<sub>2</sub><sup>+</sup>/Os(bpy)<sub>2</sub>Cl<sub>2</sub> (Os<sup>III</sup>/Os<sup>II</sup>)] simultaneously acts as the enzymatic substrate, the counterbalancing electroactive species, and the potential-guiding element, removing the requirement for additional electroactive species. Further, diaphorase (DI) is employed as the catalytic label in a sandwich-type immunosensor for prostate-specific antigen (PSA), rapidly reducing Os<sup>III</sup> to Os<sup>II</sup> in the presence of reduced nicotinamide adenine dinucleotide (NADH), enabling efficient electrochemical-enzymatic redox cycling involving the ITO electrode, Os<sup>III</sup>, DI, and NADH. By patterning the working and auxiliary electrodes 1.0 mm apart, we achieved diffusion isolation that prevents cross-talk between electrodes. After optimizing blocking, potential difference, and incubation conditions, the sensor achieved a detection limit of approximately 20 pg/mL and a detection range of 20-10 ng/mL in spiked human serum. The results of our analysis of clinical serum samples correlated closely with those of a commercial PSA assay, demonstrating both analytical accuracy and robustness. This study establishes a streamlined, point-of-care-compatible platform that achieves stable potential control and robust kinetics without a dedicated reference electrode.

ACS SensorsVol. 10(11)
Pusan National University (KR)
Openalex Percentile: Top 14%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.