Distance-Independent Synergistic Fluorescence Quenching Lateral Flow Immunoassay for Sensitive Detection of Creatine Kinase-MB Based on Gold–Iridium Oxide Nanoparticles

Fluorescence quenching lateral flow immunoassay (FQ-LFIA) has emerged as a powerful tool for the rapid detection of disease biomarkers due to its high signal-to-noise ratio and multimodality signal output. However, conventional fluorescent quenchers are constrained by specific distances and narrow absorption peaks, hindering their quenching efficiency and sensitivity for trace analyte detection. In this study, we synthesized bimetallic gold-iridium oxide nanoparticles (Au@IrO<sub>2</sub> NPs) via a seed-mediated growth method as the quenchers and constructed a distance-independent synergistic FQ-LFIA (SFQ-LFIA) platform. The Au@IrO<sub>2</sub> NPs significantly reduced the background fluorescence signal on the test line (T-line) through the inner filter effect (IFE), while their excellent catalytic activity oxidized the substrate 3,3',5,5'-tetramethylbenzidine (TMB) to generate the colored product oxidized TMB (oxTMB), which further synergistically quenched background fluorescence via a secondary IFE pathway. Using creatine kinase-MB (CK-MB) as a model biomarker, the detection limit of the Au@IrO<sub>2</sub> NPs-based SFQ-LFIA in fluorescence mode (0.71 pg/mL) was 13-fold lower than in the precatalysis (8.91 pg/mL) and at least 215-fold lower than in colorimetric mode. The platform demonstrated high accuracy in quantifying CK-MB levels in clinical serum samples, providing a novel strategy for developing advanced in vitro rapid diagnostic systems.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-10
DOI
https://doi.org/10.1021/acssensors.5c02604
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distance-Independent Synergistic Fluorescence Quenching Lateral Flow Immunoassay for Sensitive Detection of Creatine Kinase-MB Based on Gold–Iridium Oxide Nanoparticles

Shuang Zhao, Xiaoqun Gong, Jing Wang, Shenghui Li et al.
ACS Sensors
Biosensors and Analytical Detection
article

Distance-Independent Synergistic Fluorescence Quenching Lateral Flow Immunoassay for Sensitive Detection of Creatine Kinase-MB Based on Gold–Iridium Oxide Nanoparticles

Shuang Zhao, Xiaoqun Gong, Jing Wang, Shenghui Li, Jiashan Sun, Zilin Wang, Jiaxun Wang
article en

Abstract

Fluorescence quenching lateral flow immunoassay (FQ-LFIA) has emerged as a powerful tool for the rapid detection of disease biomarkers due to its high signal-to-noise ratio and multimodality signal output. However, conventional fluorescent quenchers are constrained by specific distances and narrow absorption peaks, hindering their quenching efficiency and sensitivity for trace analyte detection. In this study, we synthesized bimetallic gold-iridium oxide nanoparticles (Au@IrO<sub>2</sub> NPs) via a seed-mediated growth method as the quenchers and constructed a distance-independent synergistic FQ-LFIA (SFQ-LFIA) platform. The Au@IrO<sub>2</sub> NPs significantly reduced the background fluorescence signal on the test line (T-line) through the inner filter effect (IFE), while their excellent catalytic activity oxidized the substrate 3,3',5,5'-tetramethylbenzidine (TMB) to generate the colored product oxidized TMB (oxTMB), which further synergistically quenched background fluorescence via a secondary IFE pathway. Using creatine kinase-MB (CK-MB) as a model biomarker, the detection limit of the Au@IrO<sub>2</sub> NPs-based SFQ-LFIA in fluorescence mode (0.71 pg/mL) was 13-fold lower than in the precatalysis (8.91 pg/mL) and at least 215-fold lower than in colorimetric mode. The platform demonstrated high accuracy in quantifying CK-MB levels in clinical serum samples, providing a novel strategy for developing advanced in vitro rapid diagnostic systems.

ACS SensorsVol. 10(11)
Tianjin University (CN), Tianjin Medical University General Hospital (CN), Ministry of Education (PT)
Openalex Percentile: Top 67%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.