Clinical outcomes of bilateral implantation of a new non-diffractive extended-vision intraocular lens (AcrySof <sup>®</sup> IQ vivity)

PurposeTo report clinical (visual and refractive), spectacle independence, patient-reported outcomes following bilateral sequential implantation of a non-diffractive extended-vision intraocular lens (IOL): AcrySof IQ Vivity (DFT015 and DFTx15) in cataract surgery. This IOL provides continuous range of focus from distance to near, offering monofocal quality distance image and visual disturbances profile.MethodsRetrospective unmasked nonrandomized case series. Patients who underwent phacoemulsification and bilateral sequential implantation of AcrySof IQ Vivity, targeting minimonovision (nondominant eye targeted for between -0.25D and -0.50D). Clinical post-operative outcome measures were assessed 1-2 months postoperatively - binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity - 66 cm (UIVA), binocular uncorrected near visual acuity - 40 cm (UNVA), refraction, spherical equivalent (SE) and residual astigmatism (toric group). Spectacle independence and satisfaction systematic questionnaires (IOLSAT and Catquest-9SF) were performed. Visual disturbances were analyzed.Results181 patients were enrolled. 78 eyes were implanted with the DFTx15 (toric version). Binocular mean UDVA was -0.01 logMAR (± 0.05), binocular mean UIVA was 0.09 logMAR (± 0.08), binocular mean UNVA was 0.16 logMAR (± 0.12) and mean SE was -0.27D (± 0.36D). Mean residual astigmatism (toric group) was 0.3D (± 0.42D). Patient-reported outcomes for satisfaction and spectacle independence were excellent. Visual disturbances were rarely reported.ConclusionsImplanting this IOL using minimonovision strategy provides excellent binocular UDVA and UIVA, and good UNVA. It provides high patient satisfaction, spectacle independence (demonstrated excellent performance in systematic evaluations) and minimizes unwanted visual effects. Controlled designs and longer follow-ups are needed to confirm these findings.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2025-11-10
DOI
https://doi.org/10.1177/11206721251392630
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical outcomes of bilateral implantation of a new non-diffractive extended-vision intraocular lens (AcrySof ® IQ vivity)

Maria João Quadrado, Celso Maciel da Costa, Joaquim Murta, Telmo Cortinhal et al.
European Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Clinical outcomes of bilateral implantation of a new non-diffractive extended-vision intraocular lens (AcrySof ® IQ vivity)

Maria João Quadrado, Celso Maciel da Costa, Joaquim Murta, Telmo Cortinhal, Maria Fátima Silva, Miguel Raimundo, I. Figueiredo
article en

Abstract

PurposeTo report clinical (visual and refractive), spectacle independence, patient-reported outcomes following bilateral sequential implantation of a non-diffractive extended-vision intraocular lens (IOL): AcrySof IQ Vivity (DFT015 and DFTx15) in cataract surgery. This IOL provides continuous range of focus from distance to near, offering monofocal quality distance image and visual disturbances profile.MethodsRetrospective unmasked nonrandomized case series. Patients who underwent phacoemulsification and bilateral sequential implantation of AcrySof IQ Vivity, targeting minimonovision (nondominant eye targeted for between -0.25D and -0.50D). Clinical post-operative outcome measures were assessed 1-2 months postoperatively - binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity - 66 cm (UIVA), binocular uncorrected near visual acuity - 40 cm (UNVA), refraction, spherical equivalent (SE) and residual astigmatism (toric group). Spectacle independence and satisfaction systematic questionnaires (IOLSAT and Catquest-9SF) were performed. Visual disturbances were analyzed.Results181 patients were enrolled. 78 eyes were implanted with the DFTx15 (toric version). Binocular mean UDVA was -0.01 logMAR (± 0.05), binocular mean UIVA was 0.09 logMAR (± 0.08), binocular mean UNVA was 0.16 logMAR (± 0.12) and mean SE was -0.27D (± 0.36D). Mean residual astigmatism (toric group) was 0.3D (± 0.42D). Patient-reported outcomes for satisfaction and spectacle independence were excellent. Visual disturbances were rarely reported.ConclusionsImplanting this IOL using minimonovision strategy provides excellent binocular UDVA and UIVA, and good UNVA. It provides high patient satisfaction, spectacle independence (demonstrated excellent performance in systematic evaluations) and minimizes unwanted visual effects. Controlled designs and longer follow-ups are needed to confirm these findings.

European Journal of Ophthalmology
Hospitais da Universidade de Coimbra (PT), Escola Superior de Tecnologia da Saúde de Coimbra (PT), University of Coimbra (PT)
Openalex Percentile: Top 56%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.