Evaluation of Pressure Sensing Modalities and Lumen Design Parameters for a Novel Multifunctional Neonatal Feeding and Vital Signs Monitoring Catheter

Abstract Premature infants often require respiratory support, vital signs monitoring, and gastric feeding during intensive care, but current monitoring systems rely on external devices that can damage fragile neonatal skin. This paper presents an engineering evaluation of the airway pressure sensing feature as part of a multifunctional feeding catheter designed to integrate vital signs monitoring and airway pressure monitoring with existing feeding capabilities. Two sensing modalities—direct sensing using embedded microtransducers and remote sensing via air-filled lumens—were experimentally compared under 24-h cyclic and static pressure conditions. Results show that while embedded sensors face challenges such as drift and miniaturization constraints, a remote architecture using an external amplified sensor offers superior signal stability and ease of integration. In addition, the study characterizes how lumen length and internal diameter affect pressure transmission. Narrow or excessively long lumens introduce signal delays as long as 15 s and signal dampening, while larger, shorter lumens preserve signal fidelity. These findings provide design guidance for future development of a multifunctional neonatal feeding and monitoring catheter and define critical engineering parameters for final performance optimization and manufacturability.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-11-10
DOI
https://doi.org/10.1115/1.4070365
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Pressure Sensing Modalities and Lumen Design Parameters for a Novel Multifunctional Neonatal Feeding and Vital Signs Monitoring Catheter

Chris Rylander, Alan Groves, Angie Englert, Wei Li et al.
Journal of Medical Devices
Neonatal Respiratory Health Research
article

Evaluation of Pressure Sensing Modalities and Lumen Design Parameters for a Novel Multifunctional Neonatal Feeding and Vital Signs Monitoring Catheter

Chris Rylander, Alan Groves, Angie Englert, Wei Li, Jorge Tejada, Iman Salafian Esfahani
article en

Abstract

Abstract Premature infants often require respiratory support, vital signs monitoring, and gastric feeding during intensive care, but current monitoring systems rely on external devices that can damage fragile neonatal skin. This paper presents an engineering evaluation of the airway pressure sensing feature as part of a multifunctional feeding catheter designed to integrate vital signs monitoring and airway pressure monitoring with existing feeding capabilities. Two sensing modalities—direct sensing using embedded microtransducers and remote sensing via air-filled lumens—were experimentally compared under 24-h cyclic and static pressure conditions. Results show that while embedded sensors face challenges such as drift and miniaturization constraints, a remote architecture using an external amplified sensor offers superior signal stability and ease of integration. In addition, the study characterizes how lumen length and internal diameter affect pressure transmission. Narrow or excessively long lumens introduce signal delays as long as 15 s and signal dampening, while larger, shorter lumens preserve signal fidelity. These findings provide design guidance for future development of a multifunctional neonatal feeding and monitoring catheter and define critical engineering parameters for final performance optimization and manufacturability.

Journal of Medical DevicesVol. 20(2)
Seton Healthcare Family (US), Walker (United States) (US), The University of Texas at Austin (US)
Openalex Percentile: Top 52%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines