Case report: Retrieval of a displaced TCC fragment in the superior vena cava using single-sheath traction wire technique

Hemodialysis (HD) remains the primary renal replacement therapy for over 80% of global end-stage kidney disease (ESKD) patients, underscoring the critical need for safe and effective vascular access. Despite the high complication rates and associated morbidity/mortality of tunneled cuffed catheters (TCCs), their use remains prevalent, particularly in aging populations. We present a case where a fractured TCC fragment migrated into the superior vena cava (SVC) during catheter exchange. The fragment was successfully retrieved using a snare device with single-sheath traction wire technique, followed by in situ TCC replacement.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2025-11-09
DOI
https://doi.org/10.1177/11297298251389258
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case report: Retrieval of a displaced TCC fragment in the superior vena cava using single-sheath traction wire technique

Aijuan He, Lingling Qian, Mingxi Lu, Xiaofeng Lu et al.
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

Case report: Retrieval of a displaced TCC fragment in the superior vena cava using single-sheath traction wire technique

Aijuan He, Lingling Qian, Mingxi Lu, Xiaofeng Lu, Limin Wang, Yang Yuan
article en

Abstract

Hemodialysis (HD) remains the primary renal replacement therapy for over 80% of global end-stage kidney disease (ESKD) patients, underscoring the critical need for safe and effective vascular access. Despite the high complication rates and associated morbidity/mortality of tunneled cuffed catheters (TCCs), their use remains prevalent, particularly in aging populations. We present a case where a fractured TCC fragment migrated into the superior vena cava (SVC) during catheter exchange. The fragment was successfully retrieved using a snare device with single-sheath traction wire technique, followed by in situ TCC replacement.

The Journal of Vascular Access
Sir Run Run Shaw Hospital (CN), Tongde Hospital of Zhejiang Province (CN), Zhejiang University (CN)
Openalex Percentile: Top 49%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Case report: Retrieval of a displaced TCC fragment in the superior vena cava using single-sheath traction wire technique — Aijuan He, Lingling Qian, et al. · The Journal of Vascular Access (2025) | TGRS Research Map | TGRS