Utility of Three-Dimensional Holographic Workstation for Preoperative Simulation of Complex Congenital Heart Surgery

A 7-month-old girl with false Taussig-Bing anomaly and partial atrioventricular septal defect (AVSD) was initially considered for the single-ventricle pathway. However, preoperative evaluation using a holographic workstation enabled precise ventricular volume assessment and intraventricular rerouting simulation. A virtual baffle confirmed the feasibility of biventricular repair. Volumetric analysis and cardiac magnetic resonance imaging predicted sufficient right ventricular volume post-baffle placement. The patient underwent successful biventricular repair via the Rastelli procedure and AVSD repair. Postoperative imaging verified adequate ventricular function. The holographic workstation proved cost-effective and may help determine biventricular repair viability in complex congenital heart diseases.

Authors

Institutions

Publication Details

Journal
Interdisciplinary CardioVascular and Thoracic Surgery
Published
2025-10-28
DOI
https://doi.org/10.1093/icvts/ivaf258
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utility of Three-Dimensional Holographic Workstation for Preoperative Simulation of Complex Congenital Heart Surgery

Taisuke Nabeshima, Takaya Hoashi, Hiroyuki Takao, Takaaki Suzuki
Interdisciplinary CardioVascular and Thoracic Surgery
Anatomy and Medical Technology
article

Utility of Three-Dimensional Holographic Workstation for Preoperative Simulation of Complex Congenital Heart Surgery

Taisuke Nabeshima, Takaya Hoashi, Hiroyuki Takao, Takaaki Suzuki
article en

Abstract

A 7-month-old girl with false Taussig-Bing anomaly and partial atrioventricular septal defect (AVSD) was initially considered for the single-ventricle pathway. However, preoperative evaluation using a holographic workstation enabled precise ventricular volume assessment and intraventricular rerouting simulation. A virtual baffle confirmed the feasibility of biventricular repair. Volumetric analysis and cardiac magnetic resonance imaging predicted sufficient right ventricular volume post-baffle placement. The patient underwent successful biventricular repair via the Rastelli procedure and AVSD repair. Postoperative imaging verified adequate ventricular function. The holographic workstation proved cost-effective and may help determine biventricular repair viability in complex congenital heart diseases.

Interdisciplinary CardioVascular and Thoracic SurgeryVol. 40(11)
Saitama International Medical Center (JP), Saitama Medical University (JP)
Openalex Percentile: Top 67%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Utility of Three-Dimensional Holographic Workstation for Preoperative Simulation of Complex Congenital Heart Surgery — Taisuke Nabeshima, Takaya Hoashi, et al. · Interdisciplinary CardioVascular and Thoracic Surgery (2025) | TGRS Research Map | TGRS