Utility of Three-Dimensional Holographic Workstation for Preoperative Simulation of Complex Congenital Heart Surgery
A 7-month-old girl with false Taussig-Bing anomaly and partial atrioventricular septal defect (AVSD) was initially considered for the single-ventricle pathway. However, preoperative evaluation using a holographic workstation enabled precise ventricular volume assessment and intraventricular rerouting simulation. A virtual baffle confirmed the feasibility of biventricular repair. Volumetric analysis and cardiac magnetic resonance imaging predicted sufficient right ventricular volume post-baffle placement. The patient underwent successful biventricular repair via the Rastelli procedure and AVSD repair. Postoperative imaging verified adequate ventricular function. The holographic workstation proved cost-effective and may help determine biventricular repair viability in complex congenital heart diseases.
Authors
- Taisuke Nabeshima (ORCID: https://orcid.org/0000-0002-1642-6968)
- Takaya Hoashi (ORCID: https://orcid.org/0000-0003-0320-3682)
- Hiroyuki Takao (ORCID: https://orcid.org/0000-0002-0404-9122)
- Takaaki Suzuki
Institutions
- Saitama International Medical Center (JP)
- Saitama Medical University (JP)
Publication Details
- Journal
- Interdisciplinary CardioVascular and Thoracic Surgery
- Published
- 2025-10-28
- DOI
- https://doi.org/10.1093/icvts/ivaf258
- Primary Topic
- Anatomy and Medical Technology
- Type
- article
- Field-Weighted Citation Impact
- 0.00