Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards

Issues related to the procedure of optimizing the calibration of modern area-detector diffractometers using reference single crystals are considered. It is shown that the accuracy of measuring the unit cell parameters (UCPs) of polycrystalline samples in the Debye–Scherrer scheme can be improved by considering the eccentricity. The procedure is tested on a CeO2 polycrystalline sample (SRM674b). The value obtained for the cubic unit cell parameter a = 5.4117(2) Å differs from the reference one by 0.0002 Å, in agreement with the experiment′s absolute error. The XRD certification of a promising Y2O3 XRD standard is performed (TU 48-4-524-90; ItO-V grade; 99.999% purity; cubic unit cell parameter a is 10.6047(3) Å).

Authors

Institutions

Publication Details

Journal
Journal of Structural Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1134/s0022476625100208
Primary Topic
X-ray Diffraction in Crystallography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards

S. А. Gromilov, Yuliya Ivanova, P. S. Serebrennikova, A. L. Kudryavtsev
Journal of Structural Chemistry
X-ray Diffraction in Crystallography
article

Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards

S. А. Gromilov, Yuliya Ivanova, P. S. Serebrennikova, A. L. Kudryavtsev
article en

Abstract

Issues related to the procedure of optimizing the calibration of modern area-detector diffractometers using reference single crystals are considered. It is shown that the accuracy of measuring the unit cell parameters (UCPs) of polycrystalline samples in the Debye–Scherrer scheme can be improved by considering the eccentricity. The procedure is tested on a CeO2 polycrystalline sample (SRM674b). The value obtained for the cubic unit cell parameter a = 5.4117(2) Å differs from the reference one by 0.0002 Å, in agreement with the experiment′s absolute error. The XRD certification of a promising Y2O3 XRD standard is performed (TU 48-4-524-90; ItO-V grade; 99.999% purity; cubic unit cell parameter a is 10.6047(3) Å).

Journal of Structural ChemistryVol. 66(10)
Novosibirsk State University (RU), Nikolaev Institute of Inorganic Chemistry (RU)
Openalex Percentile: Top 73%
X-ray Diffraction in Crystallography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.