Totally Fluoroless Versus Limited Fluoroscopy-assisted Implantation: Identifying the Role of Fluoroscopy During Subcutaneous Implantable Cardioverter-defibrillator Implantation.

The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to conventional ICD systems. Although not considered mandatory, short-time fluoroscopy is used in clinical practice, both preprocedurally and intraoperatively. The aim of this study was to compare totally fluoroless versus limited fluoroscopy-assisted S-ICD implantation in terms of clinical and technical efficacy and safety. In this non-randomized, single-center study, 49 patients (24.5% women; mean age, 43.2 ± 18.4 years) at high risk for arrhythmic cardiac death underwent S-ICD implantation in the context of either primary or secondary prevention between May 2016 and June 2024 with at least 6 months of follow-up thereafter. Patients were allocated to group A (n = 25), where a totally fluoroless implantation strategy was followed (January 2023-June 2024), or group B, where a limited fluoroscopy-guided S-ICD implantation process (first 24 cases) was followed. Following implantation, a pre-discharge chest X-ray confirmed an anatomically acceptable lead position in all cases. Further, our data revealed similar acute and long-term clinical efficacy with both approaches: the success rate of defibrillation testing at 60 J was 100%, the appropriate shock rate was low (8.2%) with defibrillation therapy successful in all cases, the mean PRAETORIAN score remained in the low-risk category, and no arrhythmic deaths were recorded. The rate of inappropriate shocks was similar between groups (8% vs. 8.3%; <i>P</i> = .97 for groups A and B, respectively). Finally, no major periprocedural complications were recorded with either approach. Compared to the limited fluoroscopy-guided technique, totally fluoroless S-ICD implantation showed comparable efficacy, reliability, and safety in the present study.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-10-01
DOI
https://doi.org/10.19102/icrm.2025.16101
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Totally Fluoroless Versus Limited Fluoroscopy-assisted Implantation: Identifying the Role of Fluoroscopy During Subcutaneous Implantable Cardioverter-defibrillator Implantation.

Dimitra Tyrovola, Artemis Papadima, Stefanos Archontakis, Damianos Kolios et al.
PubMed
Cardiac pacing and defibrillation studies
article

Totally Fluoroless Versus Limited Fluoroscopy-assisted Implantation: Identifying the Role of Fluoroscopy During Subcutaneous Implantable Cardioverter-defibrillator Implantation.

Dimitra Tyrovola, Artemis Papadima, Stefanos Archontakis, Damianos Kolios, Αreti Triantafyllou, Dimitrios Venetsanos, Skevos Sideris, Sotirios Tsalamandris, Evangelos K. Oikonomou, Nikias Milaras, Panagiotis Dourvas, Tzonatan Klogkeri, Dimitrios Sirseloudis, Christos Nikolaros, Anastasios Markakos
article en

Abstract

The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to conventional ICD systems. Although not considered mandatory, short-time fluoroscopy is used in clinical practice, both preprocedurally and intraoperatively. The aim of this study was to compare totally fluoroless versus limited fluoroscopy-assisted S-ICD implantation in terms of clinical and technical efficacy and safety. In this non-randomized, single-center study, 49 patients (24.5% women; mean age, 43.2 ± 18.4 years) at high risk for arrhythmic cardiac death underwent S-ICD implantation in the context of either primary or secondary prevention between May 2016 and June 2024 with at least 6 months of follow-up thereafter. Patients were allocated to group A (n = 25), where a totally fluoroless implantation strategy was followed (January 2023-June 2024), or group B, where a limited fluoroscopy-guided S-ICD implantation process (first 24 cases) was followed. Following implantation, a pre-discharge chest X-ray confirmed an anatomically acceptable lead position in all cases. Further, our data revealed similar acute and long-term clinical efficacy with both approaches: the success rate of defibrillation testing at 60 J was 100%, the appropriate shock rate was low (8.2%) with defibrillation therapy successful in all cases, the mean PRAETORIAN score remained in the low-risk category, and no arrhythmic deaths were recorded. The rate of inappropriate shocks was similar between groups (8% vs. 8.3%; <i>P</i> = .97 for groups A and B, respectively). Finally, no major periprocedural complications were recorded with either approach. Compared to the limited fluoroscopy-guided technique, totally fluoroless S-ICD implantation showed comparable efficacy, reliability, and safety in the present study.

PubMedVol. 16(10)
Hippocration General Hospital (GR)
Openalex Percentile: Top 49%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.