An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution

The combination of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) at ultra-high field (7 Tesla) offers appealing new possibilities to probe human brain function non-invasively with high coverage, millisecond temporal precision and sub-millimeter spatial precision, unraveling cortical layers and small subcortical structures. Unfortunately, this technique has remained largely inaccessible at 7T, due to prohibitive cross-modal interference effects and physical constraints. Here, we developed a first-of-its-kind EEG-fMRI acquisition framework on a clinical 7T system combining key improvements from previous research: compact EEG transmission to reduce artifact incidence, reference sensors for artifact correction, and adapted leads for compatibility with a dense radiofrequency receive array allowing state-of-the-art fMRI sensitivity and acceleration. Two implementations were tested: one using an EEG cap adapted in-house, and another using a recently designed prototype from an industrial manufacturer, intended to be further developed into a commercial device accessible to the broader community. A comprehensive evaluation in humans showed that simultaneous acquisitions, including sub-millimeter fMRI resolution, could be conducted without detectable safety issues or major practical constraints. The EEG exerted relatively mild perturbations on fMRI quality (6-11% loss in temporal SNR), without measurably affecting the detection of resting-state networks and visual responses. The artifacts induced on EEG could be corrected to a degree where the spatial, spectral, and temporal characteristics were comparable with outside recordings, and hallmark features such as resting-state alpha and eyes-closing alpha modulation could be clearly detected. Altogether, these findings indicate excellent prospects for neuroimaging applications, which can leverage the unique possibilities achievable at 7T.

Authors

Institutions

Publication Details

Journal
Imaging Neuroscience
Published
2025-01-01
DOI
https://doi.org/10.1162/imag.a.983
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution

Mathieu Lemay, Cristina Sainz Martinez, Jessica Bastiaansen, Roland Wiest et al.
1 citations
Imaging Neuroscience
Advanced MRI Techniques and Applications
1.36
article

An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution

Mathieu Lemay, Cristina Sainz Martinez, Jessica Bastiaansen, Roland Wiest, Serge Vulliémoz, João Jorge, Tracy Warbrick, Jonathan Wirsich, Cilia Jäger
article en
1 citations

Abstract

The combination of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) at ultra-high field (7 Tesla) offers appealing new possibilities to probe human brain function non-invasively with high coverage, millisecond temporal precision and sub-millimeter spatial precision, unraveling cortical layers and small subcortical structures. Unfortunately, this technique has remained largely inaccessible at 7T, due to prohibitive cross-modal interference effects and physical constraints. Here, we developed a first-of-its-kind EEG-fMRI acquisition framework on a clinical 7T system combining key improvements from previous research: compact EEG transmission to reduce artifact incidence, reference sensors for artifact correction, and adapted leads for compatibility with a dense radiofrequency receive array allowing state-of-the-art fMRI sensitivity and acceleration. Two implementations were tested: one using an EEG cap adapted in-house, and another using a recently designed prototype from an industrial manufacturer, intended to be further developed into a commercial device accessible to the broader community. A comprehensive evaluation in humans showed that simultaneous acquisitions, including sub-millimeter fMRI resolution, could be conducted without detectable safety issues or major practical constraints. The EEG exerted relatively mild perturbations on fMRI quality (6-11% loss in temporal SNR), without measurably affecting the detection of resting-state networks and visual responses. The artifacts induced on EEG could be corrected to a degree where the spatial, spectral, and temporal characteristics were comparable with outside recordings, and hallmark features such as resting-state alpha and eyes-closing alpha modulation could be clearly detected. Altogether, these findings indicate excellent prospects for neuroimaging applications, which can leverage the unique possibilities achievable at 7T.

Imaging NeuroscienceVol. 3
University of Geneva (CH), University of Bern (CH), Swiss Center for Electronics and Microtechnology (Switzerland) (CH), University Hospital of Bern (CH), University Hospital of Geneva (CH), Brain (Germany) (DE), Centre d'Imagerie BioMedicale (CH), Geneva College (US)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Centre d'Imagerie BioMédicale
Openalex Percentile: Top 14%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.