S870 A Ubiquitous and Interoperable Deep Learning Model for Automatic Detection of Pleomorphic Gastroesophageal Lesions

Introduction: Artificial intelligence (AI) has been widely explored recently to enhance capsule endoscopy (CE), with the goal of improving the reading process efficiency. The majority of AI models focus on analyzing the small intestine and colon, while the development of esophagogastric (EG) models has been limited by the lack of frames, posing a challenge to building models with robust performance. This study aims to develop an interoperable ubiquitous model capable detecting pleomorphic lesions in the EG tract. Methods: A total of 59,482 endoscopic frames were included from 774 CE procedures conducted across 5 medical centers to train a convolutional neural network (CNN). The data were separated following an exam-based split, with 90% assigned to training set—including a 5-fold cross-validation—and the remaining 10% reserved for testing. The main performance metrics evaluated included sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve (AUC-ROC). Results: In training set, the average sensitivity was 85.0% (95% confidence interval [CI] 76.5-93.5), specificity was 96.3% (95% CI 93.9-98.7) and accuracy was 93.6% (95% CI 91.7-95.4), with an AUC-ROC of 0.98 (95% CI 0.97-0.98). In the testing phase, the sensitivity was 92.2%, specificity was 95.1%, and accuracy was 94.6%. Conclusion: AI models for CE that can evaluate the esophagus and stomach represent an important advancement toward creating a comprehensive panendoscopic system. This ubiquitous and interoperable model has shown robust accuracy in identifying lesions in both regions. Nonetheless, further prospective studies in real-world clinical settings are essential to confirm its effectiveness compared to conventional upper endoscopy.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001130940.45524.49
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S870 A Ubiquitous and Interoperable Deep Learning Model for Automatic Detection of Pleomorphic Gastroesophageal Lesions

João Ferreira, J.E. Sinclair De Frias, Miguel Martins, Tiago Ribeiro et al.
The American Journal of Gastroenterology
Gastrointestinal Bleeding Diagnosis and Treatment
article

S870 A Ubiquitous and Interoperable Deep Learning Model for Automatic Detection of Pleomorphic Gastroesophageal Lesions

João Ferreira, J.E. Sinclair De Frias, Miguel Martins, Tiago Ribeiro, João L. Afonso, Patrícia Andrade, Hélder Cardoso, Francisco Mendes, Guilherme Macedo, Joana Mota, Maria João Almeida, Catarina Araújo, Pedro Cardoso
article en

Abstract

Introduction: Artificial intelligence (AI) has been widely explored recently to enhance capsule endoscopy (CE), with the goal of improving the reading process efficiency. The majority of AI models focus on analyzing the small intestine and colon, while the development of esophagogastric (EG) models has been limited by the lack of frames, posing a challenge to building models with robust performance. This study aims to develop an interoperable ubiquitous model capable detecting pleomorphic lesions in the EG tract. Methods: A total of 59,482 endoscopic frames were included from 774 CE procedures conducted across 5 medical centers to train a convolutional neural network (CNN). The data were separated following an exam-based split, with 90% assigned to training set—including a 5-fold cross-validation—and the remaining 10% reserved for testing. The main performance metrics evaluated included sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve (AUC-ROC). Results: In training set, the average sensitivity was 85.0% (95% confidence interval [CI] 76.5-93.5), specificity was 96.3% (95% CI 93.9-98.7) and accuracy was 93.6% (95% CI 91.7-95.4), with an AUC-ROC of 0.98 (95% CI 0.97-0.98). In the testing phase, the sensitivity was 92.2%, specificity was 95.1%, and accuracy was 94.6%. Conclusion: AI models for CE that can evaluate the esophagus and stomach represent an important advancement toward creating a comprehensive panendoscopic system. This ubiquitous and interoperable model has shown robust accuracy in identifying lesions in both regions. Nonetheless, further prospective studies in real-world clinical settings are essential to confirm its effectiveness compared to conventional upper endoscopy.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 53%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.