A colorimetric aptasensor based on gold nanoparticles for point-of-care testing of cardiac troponin I

As a key biomarker in clinical diagnostics, cardiac troponin I facilitates the early diagnosis of acute myocardial infarction. This study developed a rapid quantitative method for detecting cardiac troponin I in blood, aiming to establish its quantitative correlation with myocardial infarction area by accurately quantifying the serum cTnI concentration in patients suffering from acute myocardial infarction. We utilized a cTnI-specific aptamer as the recognition element. Gold nanoparticles exhibit salt-induced aggregation with visible color change. The aptamer protects gold nanoparticles from high-salt aggregation. Through systematic optimization, we established a gold nanoparticle-based colorimetric assay leveraging this anti-aggregation mechanism. Results demonstrated that under optimal conditions—200 mM NaCl and 800 nM aptamer concentration—the developed assay exhibited a promising linear response (R 2 = 0.942) across a cardiac troponin I concentration spanning from 0.1 to 0.8 μg/mL. According to the standard calibration method, the detection limit was estimated as 0.1 μg/mL. We observed recovery rates ranging from 105.6 % to 118.5 %. This research presents a highly sensitive, specific, and rapid point-of-care detection methodology for cardiac troponin I, offering enhanced field-testing efficiency and providing a low-cost alternative for serum cardiac troponin I detection. Moreover, it lays the groundwork for the development of a novel methodology enabling dynamic and quantitative assessment of infarct size in patients suffering from myocardial infarction. • This research presents a highly sensitive, specific, and rapid point-of-care detection methodology for cardiac troponin I, offering enhanced field-testing efficiency. • Providing a low-cost alternative for serum cardiac troponin I detection. • Moreover, it lays the groundwork for the development of a novel methodology enabling dynamic and quantitative assessment of infarct size in patients with myocardial infarction.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2025-11-08
DOI
https://doi.org/10.1016/j.sbsr.2025.100910
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A colorimetric aptasensor based on gold nanoparticles for point-of-care testing of cardiac troponin I

Chunlei Zhou, Ming Tao, Zhongyang Shen, Ruyi Chen et al.
1 citations
Sensing and Bio-Sensing Research
Advanced biosensing and bioanalysis techniques
0.81
article

A colorimetric aptasensor based on gold nanoparticles for point-of-care testing of cardiac troponin I

Chunlei Zhou, Ming Tao, Zhongyang Shen, Ruyi Chen, Tingting Lan, Shuang Yang, Mingxing Yu, Zhihong Wang, Xu Duan, Junhao Wu, Yue He, Xinyue Qu, Deling Kong
article en
1 citations

Abstract

As a key biomarker in clinical diagnostics, cardiac troponin I facilitates the early diagnosis of acute myocardial infarction. This study developed a rapid quantitative method for detecting cardiac troponin I in blood, aiming to establish its quantitative correlation with myocardial infarction area by accurately quantifying the serum cTnI concentration in patients suffering from acute myocardial infarction. We utilized a cTnI-specific aptamer as the recognition element. Gold nanoparticles exhibit salt-induced aggregation with visible color change. The aptamer protects gold nanoparticles from high-salt aggregation. Through systematic optimization, we established a gold nanoparticle-based colorimetric assay leveraging this anti-aggregation mechanism. Results demonstrated that under optimal conditions—200 mM NaCl and 800 nM aptamer concentration—the developed assay exhibited a promising linear response (R 2 = 0.942) across a cardiac troponin I concentration spanning from 0.1 to 0.8 μg/mL. According to the standard calibration method, the detection limit was estimated as 0.1 μg/mL. We observed recovery rates ranging from 105.6 % to 118.5 %. This research presents a highly sensitive, specific, and rapid point-of-care detection methodology for cardiac troponin I, offering enhanced field-testing efficiency and providing a low-cost alternative for serum cardiac troponin I detection. Moreover, it lays the groundwork for the development of a novel methodology enabling dynamic and quantitative assessment of infarct size in patients suffering from myocardial infarction. • This research presents a highly sensitive, specific, and rapid point-of-care detection methodology for cardiac troponin I, offering enhanced field-testing efficiency. • Providing a low-cost alternative for serum cardiac troponin I detection. • Moreover, it lays the groundwork for the development of a novel methodology enabling dynamic and quantitative assessment of infarct size in patients with myocardial infarction.

Sensing and Bio-Sensing ResearchVol. 50
Tianjin University of Traditional Chinese Medicine (CN), Nankai University (CN), Tianjin First Center Hospital (CN), Tianjin Medical University (CN)
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.