Real-World Duration of Dexcom G7 Continuous Glucose Monitor Wear in Youth and Young Adults with Type 1 Diabetes

The Dexcom G7 continuous glucose monitor is labeled for 10 days of wear. We assessed the real-world duration of Dexcom G7 sensor wear in youth with type 1 diabetes (T1D) in this single-center retrospective cohort study. Median duration of sensor wear was calculated for youth using ≥3 sensors over a 93-day period (May 13, 2024, to August 13, 2024). Overall, 643 unique individuals (15.1 years, 45.1% female, 66.3% non-Hispanic White, 60.2% privately insured, 4.9 years T1D duration) wore 5055 sensors over the 93 days. The median sensor wear time was 8.6 days (interquartile range 7.3, 9.6). Wear time was <7.0 days for 24.8% of sensors, and just 39.9% of sensors were worn for ≥10.0 days. In summary, the real-world duration of Dexcom G7 sensor wear is <10 days for most youth with T1D. Whereas people with diabetes typically receive 36 sensors per year, with a median wear time of 8.6 days, youth would require 43 sensors or more to allow for continuous use.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2025-11-07
DOI
https://doi.org/10.1177/15209156251390821
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-World Duration of Dexcom G7 Continuous Glucose Monitor Wear in Youth and Young Adults with Type 1 Diabetes

Jacquelyn Hatch-Stein, Melissa Andrews Rearson, Brynn E. Marks, Robert Gallop et al.
Diabetes Technology & Therapeutics
Diabetes Management and Research
article

Real-World Duration of Dexcom G7 Continuous Glucose Monitor Wear in Youth and Young Adults with Type 1 Diabetes

Jacquelyn Hatch-Stein, Melissa Andrews Rearson, Brynn E. Marks, Robert Gallop, Andrew Rearson
article en

Abstract

The Dexcom G7 continuous glucose monitor is labeled for 10 days of wear. We assessed the real-world duration of Dexcom G7 sensor wear in youth with type 1 diabetes (T1D) in this single-center retrospective cohort study. Median duration of sensor wear was calculated for youth using ≥3 sensors over a 93-day period (May 13, 2024, to August 13, 2024). Overall, 643 unique individuals (15.1 years, 45.1% female, 66.3% non-Hispanic White, 60.2% privately insured, 4.9 years T1D duration) wore 5055 sensors over the 93 days. The median sensor wear time was 8.6 days (interquartile range 7.3, 9.6). Wear time was <7.0 days for 24.8% of sensors, and just 39.9% of sensors were worn for ≥10.0 days. In summary, the real-world duration of Dexcom G7 sensor wear is <10 days for most youth with T1D. Whereas people with diabetes typically receive 36 sensors per year, with a median wear time of 8.6 days, youth would require 43 sensors or more to allow for continuous use.

Diabetes Technology & TherapeuticsVol. 28(4)
Children's Hospital of Philadelphia (US), West Chester University (US), University of Pennsylvania (US)
Openalex Percentile: Top 55%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-World Duration of Dexcom G7 Continuous Glucose Monitor Wear in Youth and Young Adults with Type 1 Diabetes — Jacquelyn Hatch-Stein, Melissa Andrews Rearson, et al. · Diabetes Technology & Therapeutics (2025) | TGRS Research Map | TGRS