Evaluation of dosimetric and physical properties of a normoxic polymer gel mimicking bone-tissue

Polymer gel dosimeters, recognized for their radiological tissue equivalence, play a crucial role in clinical radiotherapy dosimetry by enabling high-resolution, three-dimensional dose mapping. They allow verification of complex treatment plans and serve as effective tools for quality assurance. Their ability to mimic human tissue and provide spatially resolved dose measurements has been extensively validated in both external beam therapy and brachytherapy. Conventional treatment planning relies on computed tomography (CT) to provide physical and electron density data of the target region. However, CT artifacts caused by metallic implants can compromise dose assessment, highlighting the need for alternative materials that accurately simulate bone tissue. This study presents a bone-equivalent, normoxic polymer gel dosimeter developed to mimic spongy bone tissue. Hydroxyapatite was incorporated into a MAGICA (methacrylic acid and ascorbic acid in gelatin with copper and agarose) formulation to achieve physical properties that closely match those of bone. Key parameters such as mass density (1.190 g cm -3 ), effective atomic number (10.07) and electron density were consistent with those of trabecular bone, as reported in ICRU Report 44. The linear attenuation coefficients of the gel were experimentally determined at 6 and 15 megavolts (MV) using a linear accelerator (LINAC) system, and the results were in good agreement with theoretical values obtained from XCOM, XMUDAT and Phy-X calculations. These findings confirm the gel’s suitability as a bone-equivalent dosimeter with promising applications in radiotherapy research and quality assurance.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms
Published
2025-11-08
DOI
https://doi.org/10.1016/j.nimb.2025.165937
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of dosimetric and physical properties of a normoxic polymer gel mimicking bone-tissue

Özlem Korkut, Salvatore Gallo, M. Erdem Sagsoz, Elif Berna Çalı et al.
Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms
Advanced Radiotherapy Techniques
article

Evaluation of dosimetric and physical properties of a normoxic polymer gel mimicking bone-tissue

Özlem Korkut, Salvatore Gallo, M. Erdem Sagsoz, Elif Berna Çalı, Alaaddin Gundes
article en

Abstract

Polymer gel dosimeters, recognized for their radiological tissue equivalence, play a crucial role in clinical radiotherapy dosimetry by enabling high-resolution, three-dimensional dose mapping. They allow verification of complex treatment plans and serve as effective tools for quality assurance. Their ability to mimic human tissue and provide spatially resolved dose measurements has been extensively validated in both external beam therapy and brachytherapy. Conventional treatment planning relies on computed tomography (CT) to provide physical and electron density data of the target region. However, CT artifacts caused by metallic implants can compromise dose assessment, highlighting the need for alternative materials that accurately simulate bone tissue. This study presents a bone-equivalent, normoxic polymer gel dosimeter developed to mimic spongy bone tissue. Hydroxyapatite was incorporated into a MAGICA (methacrylic acid and ascorbic acid in gelatin with copper and agarose) formulation to achieve physical properties that closely match those of bone. Key parameters such as mass density (1.190 g cm -3 ), effective atomic number (10.07) and electron density were consistent with those of trabecular bone, as reported in ICRU Report 44. The linear attenuation coefficients of the gel were experimentally determined at 6 and 15 megavolts (MV) using a linear accelerator (LINAC) system, and the results were in good agreement with theoretical values obtained from XCOM, XMUDAT and Phy-X calculations. These findings confirm the gel’s suitability as a bone-equivalent dosimeter with promising applications in radiotherapy research and quality assurance.

Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and AtomsVol. 570
University of Catania (IT), Kahramanmaraş Sütçü İmam University (TR), Atatürk University (TR)
Openalex Percentile: Top 57%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.