High-sensitivity spin-exchange relaxation-free (SERF) magnetometry combined with magnetic-responsive iron oxide nanoparticles for real-time monitoring of malignant tumor therapy

<b>Rationale</b>: Early and accurate evaluation of chemotherapy efficacy remains essential, yet conventional imaging approaches rely on delayed morphological changes. Functional alterations such as apoptosis and reduced metabolic activity occur earlier but are difficult to detect noninvasively. Magnetic signal detection offers a promising alternative but is limited by signal instability and biological noise. <b>Methods</b>: We developed a magnetic signal-based monitoring platform by combining magnetically responsive ferromagnetic-superparamagnetic iron oxide nanoparticle (F-SPION) with a spin-exchange relaxation-free magnetometer, with signal amplification achieved through rubidium magnetization. <i>In vitro</i>, we assessed the linear correlation between magnetic signal intensity and tumor cell number, and further evaluated doxorubicin (DOX)-induced signal changes under constant cell conditions. Prussian blue staining was used to confirm changes in F-SPION uptake. <i>In vivo</i>, F-SPION was intravenously injected into tumor-bearing mice, and magnetic signals from tumor and normal tissues were measured at multiple time points after magnetization. The mice were randomly assigned to control or doxorubicin-treated groups, and tumor signals were monitored on Days 1, 7, 14, and 21. Biocompatibility was assessed through cytotoxicity, hemolysis, histology, and blood analysis. <b>Results</b>: <i>In vitro</i>, magnetic signal intensity strongly linearly correlated with tumor cell number (R² = 0.974). Doxorubicin treatment resulted in signal reduction despite the identical cell numbers (control: 267.88 ± 5.97 pT; 24 h: 206.02 ± 2.23 pT; 48 h: 122.74 ± 2.11 pT), with Prussian blue staining confirming reduced F-SPION uptake. <i>In vivo</i>, the signal peaked at 0.5 h post-injection (1528.54 ± 23.34 pT). The tumor signals were consistently greater than the signals of normal tissues at 5 min (802.7 ± 60.8 vs. 149.3 ± 16.2 pT) and 60 min (163.6 ± 3.2 vs. 42.8 ± 1.5 pT). On Day 1, the signal of the treatment group was 425.3 ± 24.4 pT and remained stable until Day 7 (425.4 ± 14.4 pT), whereas that of the control group increased from 481.4 ± 3.8 to 830.7 ± 5.9 pT. <b>Conclusions</b>: This magnetic signal-based platform enables noninvasive, real-time, and functional monitoring of tumor response, offering a sensitive and translational strategy for early-phase therapeutic evaluation.

Authors

Institutions

Publication Details

Journal
Theranostics
Published
2025-11-07
DOI
https://doi.org/10.7150/thno.117893
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-sensitivity spin-exchange relaxation-free (SERF) magnetometry combined with magnetic-responsive iron oxide nanoparticles for real-time monitoring of malignant tumor therapy

Wenbo Wang, Qichao Cheng, Dexin Yu, Ziyuan Huang et al.
Theranostics
Characterization and Applications of Magnetic Nanoparticles
article

High-sensitivity spin-exchange relaxation-free (SERF) magnetometry combined with magnetic-responsive iron oxide nanoparticles for real-time monitoring of malignant tumor therapy

Wenbo Wang, Qichao Cheng, Dexin Yu, Ziyuan Huang, Mingchuan Yu, Min Xiang, Jiazhi Duan, Gaorui Zhang, Shiqiang Zheng, Baosheng Wang, Dawei Zhou, Ning Ding, Yuguo Chen
article en

Abstract

<b>Rationale</b>: Early and accurate evaluation of chemotherapy efficacy remains essential, yet conventional imaging approaches rely on delayed morphological changes. Functional alterations such as apoptosis and reduced metabolic activity occur earlier but are difficult to detect noninvasively. Magnetic signal detection offers a promising alternative but is limited by signal instability and biological noise. <b>Methods</b>: We developed a magnetic signal-based monitoring platform by combining magnetically responsive ferromagnetic-superparamagnetic iron oxide nanoparticle (F-SPION) with a spin-exchange relaxation-free magnetometer, with signal amplification achieved through rubidium magnetization. <i>In vitro</i>, we assessed the linear correlation between magnetic signal intensity and tumor cell number, and further evaluated doxorubicin (DOX)-induced signal changes under constant cell conditions. Prussian blue staining was used to confirm changes in F-SPION uptake. <i>In vivo</i>, F-SPION was intravenously injected into tumor-bearing mice, and magnetic signals from tumor and normal tissues were measured at multiple time points after magnetization. The mice were randomly assigned to control or doxorubicin-treated groups, and tumor signals were monitored on Days 1, 7, 14, and 21. Biocompatibility was assessed through cytotoxicity, hemolysis, histology, and blood analysis. <b>Results</b>: <i>In vitro</i>, magnetic signal intensity strongly linearly correlated with tumor cell number (R² = 0.974). Doxorubicin treatment resulted in signal reduction despite the identical cell numbers (control: 267.88 ± 5.97 pT; 24 h: 206.02 ± 2.23 pT; 48 h: 122.74 ± 2.11 pT), with Prussian blue staining confirming reduced F-SPION uptake. <i>In vivo</i>, the signal peaked at 0.5 h post-injection (1528.54 ± 23.34 pT). The tumor signals were consistently greater than the signals of normal tissues at 5 min (802.7 ± 60.8 vs. 149.3 ± 16.2 pT) and 60 min (163.6 ± 3.2 vs. 42.8 ± 1.5 pT). On Day 1, the signal of the treatment group was 425.3 ± 24.4 pT and remained stable until Day 7 (425.4 ± 14.4 pT), whereas that of the control group increased from 481.4 ± 3.8 to 830.7 ± 5.9 pT. <b>Conclusions</b>: This magnetic signal-based platform enables noninvasive, real-time, and functional monitoring of tumor response, offering a sensitive and translational strategy for early-phase therapeutic evaluation.

TheranosticsVol. 16(3)
Shandong University (CN), University of Jinan (CN), Qilu Hospital of Shandong University (CN), Beihang University (CN)
Openalex Percentile: Top 68%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.