Fabrication and Dosimetric Evaluation of a 3D-Printed Multichannel Cylindrical Applicator Prototype for HDR Gynecological Brachytherapy

High dose-rate (HDR) brachytherapy is widely used in the treatment of gynecological cancers, but the availability of multichannel applicators remains limited in many radiotherapy centers. 3D printing has emerged as a viable alternative for manufacturing customized devices, allowing for optimized dose distribution and reduced exposure to organs at risk. This study aimed to develop and evaluate a 3D-printed multichannel cylindrical applicator for gynecological brachytherapy. The printing material was selected based on its physical properties, followed by an analysis of Hounsfield Units (HU) for different infill percentages and printing patterns. The applicator was printed using polylactic acid (PLA), and different physical and imaging tests were performed. The dose distributions obtained with the 3D-printed multichannel applicator and a single-channel were compared, with focus on target coverage and organ-at-risk exposure. Dosimetric evaluation was performed using Gafchromic® EBT4 film. The results show that the multichannel applicator enabled better dose conformity, reducing rectal exposure compared to the single-channel applicator while maintaining target coverage. Gamma analysis confirmed the accuracy of the calculated dose distribution. 3D printing seems to be a viable alternative to produce customized applicators, potentially expanding therapeutic options in gynecological brachytherapy, however, future studies should investigate the biocompatibility of the material and the clinical feasibility of the applicator.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-11-07
DOI
https://doi.org/10.15392/2319-0612.2025.2889
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and Dosimetric Evaluation of a 3D-Printed Multichannel Cylindrical Applicator Prototype for HDR Gynecological Brachytherapy

Delano V. S. Batista, Saulo Santos Fortes, Patrícia Guimarães, Rechele Grazziotin Reisner
Brazilian Journal of Radiation Sciences
Advanced Radiotherapy Techniques
article

Fabrication and Dosimetric Evaluation of a 3D-Printed Multichannel Cylindrical Applicator Prototype for HDR Gynecological Brachytherapy

Delano V. S. Batista, Saulo Santos Fortes, Patrícia Guimarães, Rechele Grazziotin Reisner
article en

Abstract

High dose-rate (HDR) brachytherapy is widely used in the treatment of gynecological cancers, but the availability of multichannel applicators remains limited in many radiotherapy centers. 3D printing has emerged as a viable alternative for manufacturing customized devices, allowing for optimized dose distribution and reduced exposure to organs at risk. This study aimed to develop and evaluate a 3D-printed multichannel cylindrical applicator for gynecological brachytherapy. The printing material was selected based on its physical properties, followed by an analysis of Hounsfield Units (HU) for different infill percentages and printing patterns. The applicator was printed using polylactic acid (PLA), and different physical and imaging tests were performed. The dose distributions obtained with the 3D-printed multichannel applicator and a single-channel were compared, with focus on target coverage and organ-at-risk exposure. Dosimetric evaluation was performed using Gafchromic® EBT4 film. The results show that the multichannel applicator enabled better dose conformity, reducing rectal exposure compared to the single-channel applicator while maintaining target coverage. Gamma analysis confirmed the accuracy of the calculated dose distribution. 3D printing seems to be a viable alternative to produce customized applicators, potentially expanding therapeutic options in gynecological brachytherapy, however, future studies should investigate the biocompatibility of the material and the clinical feasibility of the applicator.

Brazilian Journal of Radiation SciencesVol. 13(4)
Instituto de Radioproteção e Dosimetria (BR), Instituto Nacional de Câncer - INCA (BR), Radiation Protection Institute (UA)
Openalex Percentile: Top 57%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication and Dosimetric Evaluation of a 3D-Printed Multichannel Cylindrical Applicator Prototype for HDR Gynecological Brachytherapy — Delano V. S. Batista, Saulo Santos Fortes, et al. · Brazilian Journal of Radiation Sciences (2025) | TGRS Research Map | TGRS