Evaluation of right adrenal vein cannulation by trans-catheter contrast-enhanced ultrasonography: A retrospective comparative study

Adrenal vein sampling (AVS), the gold standard for confirmation of primary aldosteronism (PA) subtype, is technically challenging. Here, we assessed the benefit of trans-catheter contrast-enhanced ultrasonography (CEUS) in right adrenal gland imaging and its potential to improve the right AVS success rates among inexperienced interventionalists. AVS was performed on all included PA patients (n = 61; 39 men; mean age, 52 ± 8.81 years) by a single interventionalist (who had no AVS experience prior to the study) between January 2020 and July 2022. Thirty-five patients underwent trans-catheter CEUS-assisted digital subtraction angiography (DSA)-guided AVS (CEUS-AVS), and 26 patients underwent DSA-guided AVS (DSA-AVS). In the CEUS-AVS group, following right adrenal vein cannulation, selective trans-catheter CEUS was performed to validate cannulation accuracy. Fisher exact test, two-sided Student t tests, and the Mann-Whitney test were used for statistical analysis. The right AVS success rate was higher in the CEUS-AVS than in the DSA-AVS group (94.29% vs 73.08%, P = .03), but the left and bilateral AVS success rates did not differ. The ultrasound imaging success rate of the right adrenal vein was 97.1%. Right AVS was unsuccessful in 9 patients (two in the CEUS-AVS and 7 in the DSA-AVS group). Operative times did not differ, but radiation exposure times were shorter in CEUS-AVS patients (8.4 [6.00, 12.3] vs 15.37 [7.23, 24.75], P = .04). Surgery-related complications were similar between groups. CEUS-AVS can be used to confirm right adrenal vein cannulation accuracy, help inexperienced interventionalists rapidly improve AVS success rates, and shorten radiation exposure.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-11-07
DOI
https://doi.org/10.1097/md.0000000000045563
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of right adrenal vein cannulation by trans-catheter contrast-enhanced ultrasonography: A retrospective comparative study

Lumin Chen, Feng Jiang, Chenhan Liu, Renbiao Chen et al.
Medicine
Hormonal Regulation and Hypertension
article

Evaluation of right adrenal vein cannulation by trans-catheter contrast-enhanced ultrasonography: A retrospective comparative study

Lumin Chen, Feng Jiang, Chenhan Liu, Renbiao Chen, Like Qian, Yuyu Liu
article en

Abstract

Adrenal vein sampling (AVS), the gold standard for confirmation of primary aldosteronism (PA) subtype, is technically challenging. Here, we assessed the benefit of trans-catheter contrast-enhanced ultrasonography (CEUS) in right adrenal gland imaging and its potential to improve the right AVS success rates among inexperienced interventionalists. AVS was performed on all included PA patients (n = 61; 39 men; mean age, 52 ± 8.81 years) by a single interventionalist (who had no AVS experience prior to the study) between January 2020 and July 2022. Thirty-five patients underwent trans-catheter CEUS-assisted digital subtraction angiography (DSA)-guided AVS (CEUS-AVS), and 26 patients underwent DSA-guided AVS (DSA-AVS). In the CEUS-AVS group, following right adrenal vein cannulation, selective trans-catheter CEUS was performed to validate cannulation accuracy. Fisher exact test, two-sided Student t tests, and the Mann-Whitney test were used for statistical analysis. The right AVS success rate was higher in the CEUS-AVS than in the DSA-AVS group (94.29% vs 73.08%, P = .03), but the left and bilateral AVS success rates did not differ. The ultrasound imaging success rate of the right adrenal vein was 97.1%. Right AVS was unsuccessful in 9 patients (two in the CEUS-AVS and 7 in the DSA-AVS group). Operative times did not differ, but radiation exposure times were shorter in CEUS-AVS patients (8.4 [6.00, 12.3] vs 15.37 [7.23, 24.75], P = .04). Surgery-related complications were similar between groups. CEUS-AVS can be used to confirm right adrenal vein cannulation accuracy, help inexperienced interventionalists rapidly improve AVS success rates, and shorten radiation exposure.

MedicineVol. 104(45)
Sir Run Run Shaw Hospital (CN), Zhejiang University (CN)
Openalex Percentile: Top 55%
Hormonal Regulation and Hypertension
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.