DG-DiT: Dual-Branch Gating Diffusion Transformer for Multi-Tracer and Multi-Scanner Brain PET Image Denoising

Diffusion probabilistic models (DPMs) have been demonstrated to be effective for denoising positron emission tomography (PET) images due to their ability to model complex data distributions. However, limitations in efficiency, accuracy, and generalizability remain open challenges in this area. In PET denoising, where high fidelity to the ground truth is critical, DPMs often require a large number of iterations and tend to offer limited quantitative accuracy. Moreover, traditional DPMs struggle to model variabilities in the data distribution arising from the use of multiple scanners and tracers. To address these issues, we propose a dual-branch gating diffusion transformer (DG-DiT) network for multi-tracer and multi-scanner PET denoising. The proposed DG-DiT exploits the strong distribution modeling capabilities of a diffusion transformer (DiT) to learn prior knowledge from a compact and regularized latent space. The design of the latent space enables efficient few-step diffusion. In addition, an image restoration transformer (IRT) model is employed for generating the final denoised image. The DiT backbone and the IRT both utilize a dual-branch gating mechanism to efficiently fuse information from multiple inputs. We conducted extensive experiments on multi-tracer and multi-scanner datasets. The results demonstrate that the proposed DG-DiT model achieves the highest quantitative accuracy across every scanner and tracer, with a PSNR improvement of up to 0.2 dB compared to several state-of-the-art deep learning models. Contrast-to-noise ratio evaluation shows that the proposed model is able to recover contrast in small and critical brain regions while effectively reducing noise. This suggests that the proposed DG-DiT model can consistently deliver superior denoising performance.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-01-01
DOI
https://doi.org/10.1109/trpms.2025.3630161
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DG-DiT: Dual-Branch Gating Diffusion Transformer for Multi-Tracer and Multi-Scanner Brain PET Image Denoising

Joyita Dutta, Fan Yang, Bowen Lei, Tzu-An Song et al.
IEEE Transactions on Radiation and Plasma Medical Sciences
Medical Imaging Techniques and Applications
article

DG-DiT: Dual-Branch Gating Diffusion Transformer for Multi-Tracer and Multi-Scanner Brain PET Image Denoising

Joyita Dutta, Fan Yang, Bowen Lei, Tzu-An Song, Zhengrong Zhou, Yubo Zhang
article en

Abstract

Diffusion probabilistic models (DPMs) have been demonstrated to be effective for denoising positron emission tomography (PET) images due to their ability to model complex data distributions. However, limitations in efficiency, accuracy, and generalizability remain open challenges in this area. In PET denoising, where high fidelity to the ground truth is critical, DPMs often require a large number of iterations and tend to offer limited quantitative accuracy. Moreover, traditional DPMs struggle to model variabilities in the data distribution arising from the use of multiple scanners and tracers. To address these issues, we propose a dual-branch gating diffusion transformer (DG-DiT) network for multi-tracer and multi-scanner PET denoising. The proposed DG-DiT exploits the strong distribution modeling capabilities of a diffusion transformer (DiT) to learn prior knowledge from a compact and regularized latent space. The design of the latent space enables efficient few-step diffusion. In addition, an image restoration transformer (IRT) model is employed for generating the final denoised image. The DiT backbone and the IRT both utilize a dual-branch gating mechanism to efficiently fuse information from multiple inputs. We conducted extensive experiments on multi-tracer and multi-scanner datasets. The results demonstrate that the proposed DG-DiT model achieves the highest quantitative accuracy across every scanner and tracer, with a PSNR improvement of up to 0.2 dB compared to several state-of-the-art deep learning models. Contrast-to-noise ratio evaluation shows that the proposed model is able to recover contrast in small and critical brain regions while effectively reducing noise. This suggests that the proposed DG-DiT model can consistently deliver superior denoising performance.

IEEE Transactions on Radiation and Plasma Medical Sciences
University of Massachusetts Amherst (US)
Openalex Percentile: Top 52%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.