MAX-FLASH: A compact multiangle x-ray system for clinical translation of FLASH radiotherapy

The emerging FLASH radiotherapy (FLASH-RT) technology, featuring ultrahigh dose rate (UHDR) instantaneous radiation to increase the response differences of normal tissues and tumors to ionizing radiation, is recognized as having significant clinical application value. A major challenge for its clinical translation, though, is achieving multiangle UHDR radiation at the millisecond time scale, in a compact system, to combine the FLASH effect with precise radiotherapy techniques. Building upon breakthroughs in several technologies, this study presents a compact multiangle x-ray FLASH-RT (MAX-FLASH) system that can be installed in most hospital radiotherapy treatment rooms.

Authors

Institutions

Publication Details

Journal
Physical Review Applied
Published
2025-09-30
DOI
https://doi.org/10.1103/mwx6-j35g
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MAX-FLASH: A compact multiangle x-ray system for clinical translation of FLASH radiotherapy

Chuanjing Wang, Wenhui Huang, Focheng Liu, Chuanxiang Tang et al.
Physical Review Applied
Radiation Therapy and Dosimetry
article

MAX-FLASH: A compact multiangle x-ray system for clinical translation of FLASH radiotherapy

Chuanjing Wang, Wenhui Huang, Focheng Liu, Chuanxiang Tang, Rui Qiu, Ankang Hu, Jiaru Shi, Yunsheng Han, Hao Zha, Qiang Gao, Xiaowu Deng, Xiaotong Zhang, Jian Wang, Liang Zhang, Weiping Wang, Junli Li, Ke Hu, Guoqing Liu, He Yu, Qiang Yan, Fusheng Zhang, Jinsheng Liu, Hongyu Zhu, Yaohong Liu, Jiaqi Qiu, Chenlei Guo, Huaibi Chen, Yinuo Zhu, Kuo Men
article en

Abstract

The emerging FLASH radiotherapy (FLASH-RT) technology, featuring ultrahigh dose rate (UHDR) instantaneous radiation to increase the response differences of normal tissues and tumors to ionizing radiation, is recognized as having significant clinical application value. A major challenge for its clinical translation, though, is achieving multiangle UHDR radiation at the millisecond time scale, in a compact system, to combine the FLASH effect with precise radiotherapy techniques. Building upon breakthroughs in several technologies, this study presents a compact multiangle x-ray FLASH-RT (MAX-FLASH) system that can be installed in most hospital radiotherapy treatment rooms.

Physical Review AppliedVol. 24(5)
Sun Yat-sen University (CN), Shenzhen University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), China National Chemical Engineering (China) (CN), Cancer Hospital of Chinese Academy of Medical Sciences (CN), Nuctech (China) (CN), Sun Yat-sen University Cancer Center (CN), Tsinghua University (CN)
Openalex Percentile: Top 52%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.