Image-Based Identification and Localisation of Changes in Intraoperative Brain Tumour Resection
Conventional brain tumour progression tracking methods inherently assume consistent image acquisition conditions between baseline and follow-up scans. In practice, however, MRI data often suffer from harmonisation issues due to variations in acquisition protocols, scanner settings, or patient positioning. To address this, we propose an image-based approach capable of identifying and localising changes between baseline and follow-up MRI scans without requiring independent registration or extensive pre-processing. Our registration-invariant method leverages the internal feature maps of a Siamese network composed of two segmentation models based on dilated convolutions, allowing it to learn long-context spatial features. These features are used to detect and localise changes directly from the input images, which are then enhanced using panchromatic sharpening to emphasise both high-level structural and pixel-level differences within the resulting change map. When tested on previously unseen, unregistered MRI scans, the method outperformed baseline models in identifying and localising resected tumour tissue ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>F</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> </mml:msub> <mml:mrow><mml:mo>=</mml:mo> <mml:mn>0.64</mml:mn></mml:mrow> </mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>I</mml:mi> <mml:mi>o</mml:mi> <mml:mi>U</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.57</mml:mn></mml:mrow> </mml:math> versus baseline <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>F</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> </mml:msub> <mml:mrow><mml:mo>=</mml:mo> <mml:mn>0.11</mml:mn></mml:mrow> </mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>I</mml:mi> <mml:mi>o</mml:mi> <mml:mi>U</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.07</mml:mn></mml:mrow> </mml:math> ). This performance remained robust under conditions of augmentation, noise, and misalignment ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>F</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> </mml:msub> <mml:mrow><mml:mo>=</mml:mo> <mml:mn>0.55</mml:mn></mml:mrow> </mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>I</mml:mi> <mml:mi>o</mml:mi> <mml:mi>U</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.45</mml:mn></mml:mrow> </mml:math> ), highlighting its resilience to real-world imaging variability. Overall, the proposed approach demonstrates strong robustness to spatial misalignment and offers a promising solution for tracking tumour progression and regression in clinical environments where reliable registration cannot be guaranteed.
Authors
- Maxime Chamberland
- Andrei C. Jalba (ORCID: https://orcid.org/0000-0001-9821-0767)
- Adil Jahouh
Institutions
- Eindhoven University of Technology (NL)
Publication Details
- Journal
- Journal of Imaging Informatics in Medicine
- Published
- 2025-11-07
- DOI
- https://doi.org/10.1007/s10278-025-01744-8
- Primary Topic
- Medical Image Segmentation Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00