Development of an Electrochemical Immunosensor for Detecting Coagulation Factor Xa and Perspectives in Monitoring Direct Oral Anticoagulant Therapy

This study aims to develop a point-of-care (POC) electrochemical immunosensor to monitor the anticoagulant activity of direct oral anticoagulants (DOACs) by detecting and distinguishing between the inactive (FX) and active (FXa) forms of Factor X. DOACs have transformed the management of thromboembolic disorders by selectively inhibiting FXa. Common monitoring methods are either insufficiently sensitive to DOAC levels or not widely accessible. This study demonstrates the development of a graphene-based electrochemical immunosensor modified by gold nanostructures and functionalized with anti-FX antibodies. Electrode modifications were characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and field-emission scanning electron microscopy (FESEM), showing enhanced electron transfer and increased current peaks (<i>I</i> <sub>pc</sub>: -241.4 μA, <i>I</i> <sub>pa</sub>: 244.6 μA). The sensor distinguished synthetic blood samples with FXa from negative and positive for FX (only 20 μL sample) via DPV peak area analysis (cutoff of 10.65 and 12.42 μA·V). An enzyme-linked immunosorbent assay was performed to verify antigen-antibody interactions, demonstrating less sensitivity to differentiate FX from FXa than DPV. Structural bioinformatics confirmed the loss of a 51-amino acid activation peptide in FXa, reducing molecular volume and likely affecting electrochemical response. In silico docking of seven nonpathogenic F10 variants in DOAC binding regions showed minimal impact on drug binding, supporting sensor applicability across genetic variations. This work demonstrates a sensitive, selective immunosensor for discriminating coagulation factor activation states, supporting point-of-care anticoagulant therapy monitoring.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-11-07
DOI
https://doi.org/10.1021/acsomega.5c08281
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an Electrochemical Immunosensor for Detecting Coagulation Factor Xa and Perspectives in Monitoring Direct Oral Anticoagulant Therapy

Mariana Rost Meireles, Marijane A. Krohn, GIOVANA DALPIAZ, Júlia Konzen Moreira et al.
ACS Omega
Advanced biosensing and bioanalysis techniques
article

Development of an Electrochemical Immunosensor for Detecting Coagulation Factor Xa and Perspectives in Monitoring Direct Oral Anticoagulant Therapy

Mariana Rost Meireles, Marijane A. Krohn, GIOVANA DALPIAZ, Júlia Konzen Moreira, Willyan Hasenkamp Carreira, Gabriela Victória de Mello Jantzch
article en

Abstract

This study aims to develop a point-of-care (POC) electrochemical immunosensor to monitor the anticoagulant activity of direct oral anticoagulants (DOACs) by detecting and distinguishing between the inactive (FX) and active (FXa) forms of Factor X. DOACs have transformed the management of thromboembolic disorders by selectively inhibiting FXa. Common monitoring methods are either insufficiently sensitive to DOAC levels or not widely accessible. This study demonstrates the development of a graphene-based electrochemical immunosensor modified by gold nanostructures and functionalized with anti-FX antibodies. Electrode modifications were characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and field-emission scanning electron microscopy (FESEM), showing enhanced electron transfer and increased current peaks (<i>I</i> <sub>pc</sub>: -241.4 μA, <i>I</i> <sub>pa</sub>: 244.6 μA). The sensor distinguished synthetic blood samples with FXa from negative and positive for FX (only 20 μL sample) via DPV peak area analysis (cutoff of 10.65 and 12.42 μA·V). An enzyme-linked immunosorbent assay was performed to verify antigen-antibody interactions, demonstrating less sensitivity to differentiate FX from FXa than DPV. Structural bioinformatics confirmed the loss of a 51-amino acid activation peptide in FXa, reducing molecular volume and likely affecting electrochemical response. In silico docking of seven nonpathogenic F10 variants in DOAC binding regions showed minimal impact on drug binding, supporting sensor applicability across genetic variations. This work demonstrates a sensitive, selective immunosensor for discriminating coagulation factor activation states, supporting point-of-care anticoagulant therapy monitoring.

ACS OmegaVol. 10(45)
Universidade Federal do Rio Grande do Sul (BR), Biosensores (Spain) (ES), Universidade do Vale do Rio dos Sinos (BR)
Openalex Percentile: Top 70%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.